Zibro Tosca Manuel D'utilisation page 106

Masquer les pouces Voir aussi pour Tosca:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 58
h.
PRObLeM
Control panel does not
start
Stove does not start
Alarm displayed "AlAr
no FirE"
Stove does not start
Alarm displayed "AlAr
no FirE"
4
1
106
TROUbLe shOOTing
caUse
No electrical input to
the stove
Circuit board protec-
tion fuse is burned
Control panel is faulty
Flat cable is faulty
Circuit board is faulty
The tank is empty
The burning pot is
dirty
The temperature sen-
sor has not detected
the minimum tempe-
rature threshold to
start
Ignitor is broken
Outside temperature is
too low.
Wood pellets are wet
Thermal sensor is
blocked
Hourly (30 sec) cle-
aning cycle is not in
accordance with the
used pellets
Electronic circuit board
is broken.
sOLUTiOn
Verify if the plug is connected
Replace the fuse. By authorized Zibro
technician only
Replace the control panel code
COM0266. By authorized Zibro techni-
cian only
Replace the flat cable cod. COM0240.
By authorized Zibro technician only
Replace circuit board code COM0231.
By authorized Zibro technician only
Fill the tank
Clean the burning pot. See chapter F
Empty the burning pot and start
again, if the problem continues. Start
the stove with some "fire starter"
or "fire lighters" in the fire bed. See
chapter D.1.1.2. Call authorized Zibro
technician if the problem still conti-
nuous.
Replace the ignitor, code COM0234.
By authorized Zibro technician only
Empty the burning pot and start
again, if the problem continues. Start
the stove with some "fire starter"
or "fire lighters" in the fire bed. See
chapter D.1.1.2. Call authorized Zibro
technician if the problem still conti-
nuous.
Use only dry wood pellets. See chap-
ter D.12.
Replace the sensor code COM0239. By
authorized Zibro technician only
The fire can get distuinguished during
minimum power level with some kind
of pellets. Use other pellets or reduce
the combustion air inlet opening.
Replace the electronic circuit board
code COM0231. By authorized Zibro
technician only