Display Of Operating Hours; Display Of Operating Information; Remote Control - Olsberg Tellus Aqua plus Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

After confirmation of the YES option, the DONE mes-
sage appears.
To exit the menu:
Press the OFF button to exit the RESET menu.
Press the OFF button to exit the SET STOVE
menu.
10.4.10 ECONOMY
This makes it possible to reduce the maximum power
setting with the Automatic A heating power setting of
5 to 1-4.
Press the two arrow buttons
same time.
The message MENU SET WORK appears on the
display.
Press the
button 2 times.
The message SET STOVE appears on the dis-
play.
Press the ON button to get into the menu.
Hold the
button down until the message
ECONOMY appears.
Press the ON button to arrive at the menu.
The current heating power setting will flash.
Use the
+
buttons to change the maxi-
mum heating power setting.
Press ON to confirm.
To exit the menu:
Press the OFF button to exit the ECONOMY
menu.
Press the OFF button to exit the SET STOVE
menu.
10.4.11 INSTALLER
In the Installer menu, the following parameters can
be adjusted by ± 27 % for the lowest and highest
heating levels:
pellet quantity
speed of exhaust fan
Press the ON +
The message MENÜ WERK appears on the
display.
Press the
button 1 time.
The message INSTALL appears on the display.
Press the ON button to arrive at the menu.
Enter the password 201 using both two arrow
keys and confirm with ON.
The message MENÜ MINIMAL appears on the
display.
With the
button, the MENÜ MAXIMALE menu
(highest heating level) can now be selected.
+
at the
buttons at the same time.
In order to enter the selected menu, press the
ON button.
Use the arrow keys to select the menu PELLET
MIN., ABGASVENT. MIN or LUFTVENT. MIN.
In order to enter the selected menu, press the
ON button.
The percent display flashes.
Enter the desired percentage change using both
two arrow keys and confirm with ON.
The same parameters can be changed for the
highest heating level in the MAXIMALE menu.
To exit the menu:
Press the OFF button 3x to exit the menus.
To reduce the air noise, the speed of the convection
fan can be reduced in the MAXIMALE menu. To
make sure the monitored pellet temperature does not
become too high, the device automatically switches
over to the maximum speed in intervals. The mes-
sage "E" then appears on the display.
You can find further information on "What do I adjust
and when" in section 14 "Alarm Messages".
11. Display hours of operation
The hours of operation can be displayed in the top
menu level.
Press the button
Press the button
12. Display operating data
All the current operating data can be retrieved here,
for example the software version, flue gas tempera-
ture, heating power setting, etc.
Press the OFF +
Use the
+
parameters.
The following parameters are displayed:
-
Unit model – software version
-
Starting time
-
Flue gas temperature
-
Room temperature
-
Room target temperature
-
Water temperature
-
rpm exhaust gas ventilator
-
Pump ON/OFF
-
Pellet temperature
-
Heating power level 01=P1/04=P2/08=P3/
-
Screw conveyor (rotating time <8.0")

13. Remote control

36
= Display of the hours of
operation so far
= Display the hours of
operation until the next
special service
buttons at the same time.
buttons to select the individual
012=P4/016=P5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

43/139

Table des Matières