6. Installing the chimney stove
The installation base must be flat and level. The
chimney stove may only be installed on an adequate-
ly sturdy base. In order to protect the floor covering,
the chimney stove may be placed on a metal floor
sheet or glass plate.
A stable and heat resistant base must be used on
combustible flooring or carpet. This must extend be-
yong the combustion chamber of the chimney stove
by 50 cm towards the front and 30 cm on each side.

7. Assembly instructions

Determine the exact installation location. No
flammable objects or materials may be posi-
tioned or stored within the radiance range, i.e. a
distance of 80 cm from the viewing glass of the
chimney stove.
Minimum distance between the unit and
flammable or supporting walls:
A = adjacent wall
B = back wall
C = side wall
D = floor protection
Install the pipe lining (on-site) into the chimney.
The height of connection can be determined indi-
vidually, but should not exceed 1.5 m from the
connector fittings. In the case of inserting through
flammable material, no flammable materials
should be found within a radius of 20 cm of the
stove pipe.
Connect the stove pipe (on-site) to the D=Ø80
mm connector fittings of the chimney stove.
Slide the chimney stove on the intended installa-
tion site and align it so that the stove pipe fits into
the pipe lining.
Important:
The stove pipe connections must be sealed tight
and leak-proof.
We recommend the use of Olsberg stove pipes
with a sealing lip.
In order to clean the connection pipes, bends
with cleaning openings must be used.
The stove pipe may not extend into the chimney.
Please remember that the surrounding walls and
installation base may reach a temperature of up to
85°C according to the test regulation EN 13240, and
this may cause discolouration to wallpaper, floor cov-
erings such as cork or similar construction materials.
7.1. Water Installation
Important:
The respective local regulations and special rules
are to be observed.
Work on water and electrical connections may
only be performed by specialists.
In addition to the required safety components, a
return flow bypass valve that increases the return
flow temperature to at least 55°C must always be
installed.
The chimney stove may never be operated
without water.

8. Start-up and operation

The pellet-burning chimney stove is connected
by the attachment plug found on the unit to a
230V power socket, which is protected by a cir-
cuit breaker.
Switch the main switch on the back side of the
unit to "I".
An acoustical signal is sounded and the display
is activated.
Fill the pellet container with pellets.
The operator language under point 10.4.3 select