TECHNICAL DATA
Voltage range ......................................................12 V
Quick charge current ..........................................3.0 A
Maintaining charge ............................................500 mA
Battery charging time Li-Ion 1.5 Ah ....................30 min
Weight without cable .........................................460 g
WARNING! Read all safety warnings and all
instructions, including those given in the accompanying
brochure. Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Please pay attention to the safety instructions in the
attached leaflet!
Do not dispose of used battery packs in the household
refuse or by burning them. Milwaukee Distributors offer to
retrieve old batteries to protect our environment.
Do not store the battery pack together with metal objects
(short circuit risk).
Use only System C 12 chargers for charging System C 12
battery packs. Do not use battery packs from other systems.
The following battery packs can be charged with this
charger:
voltage
battery
rated
capacity
battery
12 V
C12 B
≤ 1.5 Ah
12 V
C12 BX
≤ 3.0 Ah
2 x 3
12 V
M12 B
≤ 1.5 Ah
12 V
M12 BX
≤ 3.0 Ah
2 x 3
Do not try to charge non-chargeable batteries with this
charger.
No metal parts must be allowed to enter the battery section
of the charger (short circuit risk).
Never break open battery packs and chargers and store
only in dry rooms. Keep dry at all times.
Do not touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new
one.
Before use check machine, cable, and plug for any
damages or material fatigue. Repairs should only be carried
out by authorised Service Agents.
This appliance is not intended for use by persons (including
children) with limited physical, sensory or mental capabilities
or insufficient experience and/or knowledge unless they are
supervised by a person who is responsible for their safety or
have been instructed by them in the safe use of the tool.
Children should be supervised in order to ensure that they
do not play with the appliance.
SPECIFIED CONDITIONS OF USE
The quick charger can charge Milwaukee batteries from C
12 to 12 V.
Do not use this product in any other way as stated for
normal use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the
system voltage indicated on the rating plate. It is also
possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
6
ENGLISH
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is
in conformity with the following standards or standardized
documents. EN 60335, EN 55014-1, EN 55014-2,
EN 61000-3-2, EN 61000-3-3, EN 62 233, in accordance
with the regulations 2006/95/EC, 2004/108/EC
Rainer Kumpf
Winnenden, 2008-01-14
Manager Product Development
BATTERIES
New battery packs reach full loading capacity after 4 - 5
chargings and dischargings. Battery packs which have not
been used for some time should be recharged before use.
Temperatures in excess of 50°C (122°F) reduce the
performance of the battery pack. Avoid extended exposure
to heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept
clean.
CHARACTERISTICS
After inserting the battery into the reception of the charger
the battery will automatically be charged (red lamp is
No. of
illuminated continuously)
cells
When a hot or cold battery pack is inserted into the charger
(flashing red lamp), charging will begin automatically once
3
the battery reaches the correct charging temperature
(0°C...60°C).
3
Charging time varies depending on the battery temperature,
charge needed and the type of battery pack being charged.
As soon as charging is completed, the charger switches
over to "trickle" charge to maintain the full capacity (green
control lamp is illuminated continuously, red lamp off)
It is not necessary to remove the battery after charging. The
battery can be stored permanently in the charger without the
danger of being overcharged.
If both LEDs flash at the same time, either the battery has
not been completely mounted or there is a fault in the
battery or the charger. For safety reasons you must stop
using the charger and battery immediately and have them
inspected by an Milwaukee Customer Service Centre.
MAINTENANCE
If the supply cord of this appliance is damaged, it must only
be replaced by a repair shop appointed by the manufacturer,
because special purpose tools are required
Use only Milwaukee accessories and Milwaukee spare
parts. Should components need to be replaced which have
not been described, please contact one of our Milwaukee
service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the Article No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: Milwaukee Electric Tool,
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully
before starting the machine.
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2002/96/EC on waste
electrical and electronic equipment and its
implementation in accordance with national law,
electric tools that have reached the end of their
life must be collected separately and returned to
an environmentally compatible recycling facility.
This tool is only suitable for indoor use. Never
expose tool to rain.
Do not burn used battery packs.
Never charge a damaged battery pack. Replace
by a new one.