The generator produces enough electric power to cause a serious
shock or electrocution if misused.
Be sure to ground the generator when the connected appliance is
grounded.
To ground the terminal of the
generator, use a cooper wire with
same or larger diameter than the
cord of the connected appliance.
Use extension cord set with ground conductor when connecting an
appliance with ground conductor.
To identify the Ground pin in the plug, see RECEPTACLE page
Connect a RCBO (Residual current circuit breaker with overload
protection) of 30 mA ground fault detection and cut-off of less than 0.4
seconds at more than 30 A of output current, if you are using two or
more appliance.
Follow the instructions provided by each RCBO manufacturer before
use.
GENERATOR
Connecting with one RCBO
Improper connections to a building's electrical system can allow
current from the generator to backfeed into the utility lines.
Such backfeed may electrocute utility company workers or others
who contact the lines during a power outage, and the generator may
explode, burn, or cause fires when utility power is restored.
Consult the utility company or a qualified electrician prior to making
any power connections.
APPLIANCES
RCBO
6.

GENERATOR USE

GROUND
TERMINAL
RCBO
GENERATOR
RCBO
Connecting with two RCBO
56
.
APPLIANCES