ABB DCS 600 MultiDrive Mode D'emploi page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

For compliance with the protection objectives of
the German EMC Act (EMVG) in systems and
machines, the following EMC standards must
be satisfied:
Product Standard EN 61800-3
EMC standard for drive systems (PowerDriveSys-
tem), interference immunity and emissions in resi-
dential areas, enterprise zones with light industry
and in industrial facilities.
This standard must be complied with in the EU for
satisfying the EMC requirements for systems and
machines!
Second environment (industry) with restricted distribution
satisfied
Medium-voltage network
Supply transformer for a
Industrial zone
residential area (rating
normally ≤ 1.2 MVA)
Earthed
neutral
Earthed 400-V network
with neutral conductor;
3~ ≤ 400 A
Mains filter
Line reactor +
Line reactor
Y-capacitor
Converter
Converter
M
M
M
M
Operation at low-voltage network together with
other loads of all kinds, apart from some kinds
of sensitive communication equipment.
for further information:
Technical Guide
3ADW000163
For emitted interference, the following apply:
EN 61000-6-3 Specialised basic standard for emissions in light industry can
EN 61000-6-4 Specialised basic standard for emissions in industry
For interference immunity, the following apply:
EN 61000-6-1 Specialised basic standard for interference immunity in residen-
EN 61000-6-2 Specialised basic standard for interference immunity in indus-
* The generic standards are given in brackets
Not applicable
on customer's request
satisfied
Medium-voltage network
Industrial zone
Converter
transformer
Converter
M
M
Operation with separate power converter transformer. If there
are other loads at the same secondary winding, these must be
able to cope with the commutation gaps caused by the power
converter. In some cases, commutating reactors will be
required.
3ADW000179R0100_DCS600_QuickGuide_edisf_a
be satisfied with special features (mains filters, screened power
cables) in the lower rating range *(EN 50081-1).
*(EN 50081-2)
tial areas *(EN 50082-1)
try. If this standard is satisfied, then the EN 61000-6-1 standard
is automatically satisfied as well *(EN 50082-2).
Standards
EN 61800-3
EN 61000-6-3
satisfied
EN 61000-6-4
EN 61000-6-2
EN 61000-6-1
Converter
transformer
with earthed
iron core
(and earthed
I > 400 A
screen where
and/or
appropriate)
U > 500 V
Line reactor
Converter
M
M
Classification
The following overview
utilises the terminolo-
gy and indicates the
action required in ac-
cordance with Product
Standard
EN 61800-3
For the DCS 500B se-
ries, the limit values for emitted
interference are complied with,
provided the action indicated is
carried out. This action is based
on the term Restricted Distri-
bution used in the standard
(meaning a sales channel in
which the products concerned
can be placed in the stream of
commerce only by suppliers,
customers or users which indi-
vidually or jointly possess tech-
nical EMC expertise).
For power converters without
additional components, the fol-
lowing warning applies:
This is a product with restrict-
ed obtainability under IEC
61800-3. This product may
cause radio interference in
residential areas; in this case,
it may be necessary for the
operator to take appropriate
action (see adjacent dia-
grams).
The field supply is not depicted in
this overview diagram. For the
field current cables, the same
rules apply as for the armature-
circuit cables.
Legend
Screened cable
Unscreened cable with restriction
I 9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dcs 601Dcs 602

Table des Matières