W 450 SE
Viscosity, valve, round nozzle and multi­step electronic system setting
data Multi­step electronic system
Fine­adjustment knob: For variable adjustment
Material
Resin primers
Resin lacquers
Acrylic lacquers
Radiator paints,
Hammer finish paints
Timber impregnating
Aluminium paints
Underbody protection
(wax and bitumen base)
Plastic emulsions***
Latex paints ***
*
Standard nozzle
*** With paints, which contain fine quartz or other similar components, there is increased
wear of the valve and the nozzle. According to the scope of work, always have spare
parts available.
Measuring the Viscosity
Dip the viscosity test cup (Illus. 3) completely into the spray material. Hold the test cup up
and measure the time (in seconds) until the liquid empties out. Compare the measured
"runout time" with the Viscosity Table.
Valve data (handling table page 15)
The nozzle can be removed using the nozzle spanner. The valve is behind the nozzle
and comprises:
Handling table
Viscosity
DIN­s
20 - 30
20 - 30
20 - undiluted
25 - 35
undiluted
20 - 30
max. 80 - 100
not measurable
approx. 10-20%
dilution
not measurable
approx. 5 - 20%
dilution
** Part No. see accessory list page 18.
1. Atomizer head
2. Spring
3. Valve taper
Valve:
Round
Atomizer
nozzle:
colour
black
0,8*
black
0,8
black
0,8
black
0,8
black
0,8/1,2**
black
0,8
black
1,2**
white
0,8
1,0**
white
0,8
1,0**
GB
Step electronic
system
Adjustment %
50/25/12
50/25/12
50/25/12
50/25/12
100
50/25/12
100
100
100
50/25/12
15

Publicité