Panasonic WV-CL930 Mode D'emploi page 16

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WV-CL934
Select either 24 V AC or 12 V DC for
power supply and connect the power
supply to the AC/DC power terminal.
Caution:
To prevent fire or electric shock haz-
ard, use a UL listed cable (VW-1, style
1007) for the 24 V AC or 12 V DC
Input Terminal.
m
Adjust the camera angle by loosening the screw of the camera mounting base
while viewing the video monitor.
Be sure to loosen the screw of the camera mounting base when the camera angle is
adjusted. If the camera angle is changed when the screw is tight, excessive force is
applied to the camera mounting base and camera, and accordingly they may be dam-
aged. Be sure to tighten the screw securely after camera angle adjustment.
,
Adjust the focus.
When an auto iris lens is used, the originally adjusted focus may be slightly off depending
on the iris state resulting from the focal depth of the lens. In such a case, open the iris by
darkening the subject as much as possible and adjust the focus, and the focus-off state
can be prevented.
Use of "ABF" of "BACK-FOCUS SETUP" in the setup menu ( page 45) allows users to
adjust the focus optimally in the range of the capability to automatically follow the variation
in illuminance. (Note: The adjusted focal point is not necessarily the same as the optimal
focal point at the specified illuminance.)
• The out-of-focus level in the near-infrared light region may be higher than that in the
visible light region.
Setting "C/L ←→ B/W" of "BACK-FOCUS SETUP" to "AUTO" or "PRESET" in the setup
menu allows users to adjust the focus in both the near-infrared light and visible light
regions. (The variation in illuminance is not followed after focus adjustment.)
How to use varifocal lens/zoom lens
• Reset the back focus position to the CS mount default position before the back focus
adjustment. (Press the right and left buttons among the operation buttons simultaneously,
or move the cursor to "MANUAL-ADJ" of "BACK-FOCUS SETUP" in the setup menu and
press the right and left buttons simultaneously after pressing the setting button.)
• Be aware that the adjustment method varies with varifocal lens or zoom lens models. For
further information, refer to the operating instructions for the lens to be used.