3. Assembly

3. Assembly
Versions for vertical installation (Fig. 1)
Install WIKA magnetic operated float switches according to their
model (flange or thread [3])
Use the screws and nuts suitable for the flange for flange models.
Fit a suitable gasket (4) for sealing. Make sure it is installed in the
right position. (max. deviation from the vertical ± 30°)
The float (7) must be removed before installation in openings with a
diameter smaller than the diameter of the float
Mark the position of the set collars (6) before removing
If top and bottom of the floats are not already marked, please do
so now
Replace the float inside the tank after installing the magnetic
operated float switch
Then fix the set collars (6) back in the same position
The number of floats and position of stop rings are dependent on
the switching positions and number of switch points
Versions for horizontal installation (Fig. 2)
Magnetic operated float switches for horizontal operation must be
installed as shown in figure 2.
Use the screws and nuts suitable for the flange for flange models. Fit
a suitable gasket (4) for sealing. Make sure it is installed in the right
position. (The float must be tilted downwards in the unactivated state).
When installing in the union, make sure that the tilting of the float is
not affected.