Fig. 9.3
DISCHARGING PRODUCTS OF
COMBUSTION
Extractor hoods connected directly to the
outside must be provided, to allow the
products of combustion of the gas
appliance to be discharged (fig. 9.2).
If this is not possible, an electric fan may
be used, attached to the external wall or
the window; the fan should have a capa-
city to circulate air at an hourly rate of 3-
5 times the total volume of the kitchen
(fig. 9.3).
The fan can only be installed if the room
has suitable vents to allow air to enter,
as described under the heading
"Choosing suitable surroundings".
Elements illustrated in fig. 9.2 - 9.3:
A = Air vent
C = Extractor hood for products of com-
bustion
E = Electric fan to extract products of
combustion
EVACUATION DES PRODUITS DE LA
COMBUSTION
Le produits de la combustion de l'appa-
reil à gaz doivent être évacués au moyen
d'une hotte reliée directement à l'exté-
rieur (fig. 9.2).
Dans le cas contraire, il est possible
d'utiliser un ventilateur électrique, appli-
qué au mur extérieur ou à la fenêtre,
ayant une capacité apte à garantir un
changement horaire d'air égal à 3-5 fois
le volume de la cuisine (fig. 9.3).
Le ventilateur peut être installé unique-
ment en cas de présence des ouvertures
pour l'entrée de l'air, voir description cha-
pitre "Local d'installation".
Composants illustrés sur la fig. 9.2 - 9.3:
A = Ouverture pour entrée de l'air
C = Hotte d'évacuation produits de la
combustion
E = Ventilateur électrique évacuation
produits de la combustion