GAS COOKERS
CHOOSING SUITABLE SURROUNDINGS
In the room chosen to accommodate the
gas appliance, there must be an ade-
quate natural draft to allow combustion
of the gas.
The natural draft must be produced
directly by one or more vents made in
the external walls and providing a total
2
opening of at least 100 cm
The vents must be positioned close to
the floor, preferably on the opposite side
to the combustion discharge outlet and
must be designed in such a way that
they cannot be obstructed either from
the inside or the outside.
When it is not possible to provide the
necessary vents, the draft may be sup-
plied from an adjacent room, ventilated
in the required manner, provided it is not
a bedroom or an area at risk.
In this event, the door of the kitchen
must be opened to allow the draft to
enter the room.
CUISINIERES A GAZ
LOCAL D'INSTALLATION
La pièce dans laquelle l'appareil à gaz
est installé doit avoir un apport d'air
nécessaire à la combustion du gaz.
L'apport d'air doit s'effectuer directement
depuis une ou plusieurs ouvertures prati-
quées au niveau des murs extérieurs,
ayant une section libre d'au moins 100
2
cm
au total.
.
Les ouvertures devraient être posi-
tionnées à proximité du sol et, de préfé-
rence, du côté opposé par rapport à
l'évacuation des produits de combustion,
elles doivent être construites de façon à
ne pas pouvoir être bouchées, tant de
l'intérieur que de l'extérieur.
Lorsqu'il n'est pas possible de pratiquer
les ouvertures nécessaires, l'air peut
provenir d'une pièce adjacente, avec
ventilation appropriée, à condition qu'il
ne s'agisse pas d'une chambre à cou-
cher ou d'une pièce dangereuse.
Dans, ce cas, la porte de la cuisine doit
permettre le passage de l'air.