Product Features

The numbering of the product features refers to the illustra-
tion of the inspection camera on the graphics page.
1 Hand unit
2 Increase-brightness button "+"
3 On/Off button
4 Reduce-brightness button "–"
5 Display
6 Camera cable
7 Camera head
8 Camera lens
9 Illumination light in camera head
10 Battery pack*
11 Battery unlocking button
12 Camera cable, extension*
13 Socket sleeve of camera connection
14 Camera connection
15 Magnet
16 Hook
17 Mirror
18 Video output socket
19 Video cable
*Accessories shown or described are not part of the standard de-
livery scope of the product. A complete overview of accessories
can be found in our accessories program.

Technical Data

Digital Inspection Camera
Article number
Rated voltage
Operating temperature
Storage temperature
(hand unit without battery)
Relative humidity
Smallest bending radius of camera
cable
Diameter of camera head
Depth-of-field range of camera
lens
Display size
Display resolution
Format of video output
Operating life time, approx.
Weight according to
EPTA-Procedure 01/2003
Dimensions
(length x width x height)
1) Free of moisture condensation
Bosch Power Tools
Assembly
 Before any work on the inspection camera itself (e.g.
assembling, maintenance, etc.) as well as when trans-
porting and storing, remove the battery from the in-
spection camera.

Battery Charging

 Use only the battery chargers listed on the graphics
page. Only these battery chargers are matched to the lith-
ium-ion battery used in your inspection camera.
Note: The battery is supplied partially charged. To ensure full
capacity of the battery, completely charge the battery in the
battery charger before using your power tool for the first time.
The lithium ion battery can be charged at any time without re-
ducing its service life. Interrupting the charging procedure
does not damage the battery.
The battery is equipped with a NTC temperature control
which allows charging only within a temperature range of be-
tween 0 °C and 45 °C. A long battery service life is achieved
in this manner.
Battery Charge-control Indication
When the inspection camera is switched on, the charge con-
dition of the battery is indicated on the display 5:
Indication
GOS 10,8 V-LI
3 601 B41 000
Removing the battery
V=
10.8
To remove the battery 10, press the battery unlocking but-
°C
–20...+65
tons 11 and pull the battery toward the rear out of the inspec-
tion camera. Do not exert any force when doing this.
°C
–30...+80
Mounting the Camera Cable (see figure A)
1)
%
5 –95
For operation of the inspection camera, the camera cable 6
must be mounted to the hand unit 1.
mm
120
Insert the camera cable 6 into the camera connection 14 in
mm
17/9.5
such a manner that the pin of the camera cable engages into
the opening of the camera connection as shown in the figure.
mm
38 –∞
Slide the socket sleeve 13 on the camera connection over the
mm
68.6
camera cable and hand-tighten in clockwise direction.
320 x 240
To remove the camera cable 6, unscrew socket sleeve 13 in
NTSC
anticlockwise direction and pull the camera cable off.
h/Ah
11.5
Mounting the Camera Cable Extension (Accessory)
To mount a camera cable extension 12, the mounted camera
kg
0.68
cable 6 must be removed.
Then, mount the extension 12 onto camera connection 14 as
mm
166 x 66 x 45
described under "Mounting the Camera Cable" and tighten.
If required, further extensions can be mounted in the same
manner. However, the image quality decreases when exceed-
ing a total length approx. 10 m (incl. camera cable).