Installation and operating instructions
ATTENTION
WARNING
IMPORTANT ☞
Compact ceiling-mounted units KWL EC 220/340 D
The KWL unit must not be operated at the same time as solid fuel fireplaces and not in residential units
with room air-dependent fireplaces, which are connected to multiple exhaust systems.
Any existing combustion air ducts and exhaust systems for solid fuel fireplaces must be capable of being
shut off for the proper operation of the ventilation system established with a ventilation unit with heat
recovery.
We recommend that you consult the responsible chimney sweep in order to accommodate your wishes
TIP!
before purchasing an underpressure monitoring system for fireplaces.
Monitoring systems are always integrated in the unit supply cable! (see circuit diagram SS-1043)
ATTENTION DANGER TO LIFE! The use of the external contact (function 1; enable/disable unit) of
the KWL-EM or the KWL-CO
not permissible.
We recommend contacting the responsible chimney sweep before the acquisition of a monitoring system,
to take account of any requirements.
1.12

Technical data

KWL EC 220 D R/L
Voltage/Frequency
Rated current – ventilation
Pre-heater (outlet)
Pre-heater rated current
Max. total
Electrical power feed to UV
Connection cable analogue
Connection cable digital
Connection cable LAN
KWL EC 340 D R/L
Voltage/Frequency
Rated current – ventilation
Pre-heater (outlet)
Pre-heater rated current
Max. total
Electrical power feed to UV
Connection cable analogue
Connection cable digital
Connection cable LAN
1.13

Important unit components

/ KWL-VOC as a shutdown method for underpressure monitoring is
2
~ 230 V/ 50/60 Hz
Connection acc. to circuit diagram
1.2 A
Temperature operating range
1.0 kW
Ambient temperature (site)
4.4 A
Weight approx.
1.2 A (5.6 incl. pre-heater)
Protection to
2
NYM-J 3 x 1.5 mm
Summer bypass
Modular ribbon cable 6-wire
Standby losses
Modular ribbon cable 4-wire
Air flow rates V m3/h
CAT 6
~ 230 V/ 50/60 Hz
Connection acc. to circuit diagram
2.4 A
Temperature operating range
1.0 kW
Ambient temperature (site)
4.4 A
Weight approx.
2.4 A (6.6 incl. pre-heater)
Protection to
2
NYM-J 3 x 1.5 mm
Summer bypass
Modular ribbon cable 6-wire
Standby losses
Modular ribbon cable 4-wire
Air flow rates V m3/h
CAT 6
3
GB
SS-1043
-20 °C to +40 °C
+10 °C to +40 °C
50 kg
IP20
Automatic
No operation
245 (level 9)
SS-1043
-20 °C to +40 °C
+10 °C to +40 °C
70 kg
IP20
Automatic
No operation
380 (level 9)