Messages; Information And Error Messages Handytig; Dc Controlpro; Error Messages Handytig 180 Dc Basicplus - LORCH HandyTIG 180 DC ControlPro Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 156

Messages

17
Messages
17.1
Information and error messages HandyTIG 180 DC ControlPro
Code
Symptom
EEProm write/read error
H06
Thermal overload
E01
Power section
E02
E03
Current sensor
E06
Overvoltage
Supply voltage 15V
E07
Torch/remote control
E10
E14
Control panel
17.2

Error messages HandyTIG 180 DC BasicPlus

Symptom
LED mains 37 and LED malfunc-
tion 35 are not lit
LED mains 37 is lit and LED mal-
function 35 flashes
LED mains 37 is lit, but no welding
current
LED malfunction 35 is lit con-
stantly
10.15
Cause
Communication with EEProm faulty
Duty cycle exceeded
Fan defective
Power section start-up faulty
Current sensor defective
Mains voltage too high
Fault internal supply voltage
Remote control, torch or connections
defective
Component group control panel faulty
Cause
mains fuse defect
neutral, mains phase missing
machine error
ground cable not connected or de-
fect
electrode holder or torch not con-
nected or defect
machine is overheated, ED ex-
ceeded
Remedy
Switch machine off and on again, exe-
cute master reset
Allow switched-on machine to cool down
for a few minutes.
Switch unit off and on, fan must start up
for a short period, inform service.
Inform Service
Inform Service
Check mains voltage
Inform Service
Check or replace torch and remote con-
trol
Inform Service
Remedy
exchange mains fuse
check mains cable / mains extension cable
Turn off machine, wait until LED mains 12 is off,
turn machine on again If malfunction still persits,
contact Service
check ground cable, exchange if necessary
check electrode holder or torch, exchange if
necessary
let machine cool down in standby
- 39 -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Handytig 180 dc basicplus

Table des Matières