Télécharger Imprimer la page

tau D747M Notice D'installation page 16

Masquer les pouces Voir aussi pour D747M:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

CONTROL PANEL FOR ONE-TWO 12V MOTORS WITH ENCODER
LOGICS WITH MICROPROCESSOR
STATUS OF INPUTS SIGNALLED BY LEDs
"PEDESTRIAN GATE" FUNCTION
INCORPORATED FLASHING CIRCUIT
ENCODER SENSOR FOR OBSTACLE DETECTION AND SELF-LEARNING OF TRAVEL
RECEIVER CONNECTOR
BATTERY AND BATTERY CHARGER CONNECTOR (OPTIONAL)
DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid
breakdowns of the line and false contacts.
-
do not re-use old pre-existing cables.
-
we recommend to use the TAU cable code M-03000010C0 to connect the motors to the
control board.
TESTING
When you have completed the connection:
All the green LS LEDs must be on (each of them corresponds to a Normally Closed input).
The go off only when the controls to which they are associated are operated.
All the red LS LEDs must be off (each of them corresponds to a Normally Open input). The
light up only when the controls to which they are associated are operated.
TECHNICAL FEATURES
Board power supply
Max motor 1 power DC
Max motor 2 power DC
Fast acting fuse for protection of input power supply 13,5V AC (F1 - 5x20)
Fast acting fuse for motor 1 protection (F2 - 5x20)
Fast acting fuse for motor 2 protection (F3 - 5x20)
Fast acting fuse for protection of auxiliary circuits 18V DC (F4 - 5x20)
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
DIAGNOSTICS LED
DL1
PEDESTRIAN button red LED signal
DL2
OPEN/CLOSE button red LED signal
DL3
ERRORS red LED signal
DL4
STOP button green LED signal
DL5
INTERNAL PHOTOCELL green LED signal
DL6
EXTERNAL PHOTOCELL green LED signal
16
D747M
13,5V AC - 50 Hz
50 W - 18V DC
50 W - 18V DC
F 16 A
F 10 A
F 10 A
F 5 A
18V DC
18V DC
5V DC
-20 °C ÷ +55 °C

Publicité