Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fig. 4.2
B
A
Fig. 4.3
4.2.1
Installation
• Mount the wall mounting bracket (Fig. 4.2 A). See Fig. 4.2
for the recommended height and the drilling dimensions.
Note that the mounting height given only applies if the
extraction arm is mounted at 2,600 mm (102.4 in.) and
the SFS is horizontally in line with the outlet opening of the
extraction fan. Make sure there is sufficient space at the
top (min. 700 mm [27.6 in.]); when replacing the filter the
cover must be removed.
• Position the complete SFS (Fig. 4.3 A) over the wall bracket
(Fig. 4.3 B).
• Subsequently, as desired, mount on the inlet opening of
the SFS:
- a spiralo-tube (Ø 160 mm [6.3 in.]), over the T-profile;
- a CKS (flexible extraction hose [Ø 160 mm/6.3 in.] with
two hose clamps).
• Saw one or both outlet opening(s) open (they are located
in the recesses of the dust barrel) and, if necessary,
connect the outlet opening(s) to an air duct system.
• Check that the complete extraction system is airtight. If it
is not allowed to recycle the air, connect the outlet opening
to an air duct system which leads the air to the outside.
• Finally, lock the complete unit by inserting two bolts in the
slotted holes in the filter body; this is necessary.
0507320010/061112/D SFS
Installation of the prefilter box
To install the prefilter box, refer to the instruction sheet.
4.2.2
Electric connection
The 24 VAC supply for the SFS is obtained via the CB control
box. For this purpose the supply cable (NCW-11) and the cap
nut (PG-7) are also included. The cap nut must be mounted in
the CB.
• Connect the NCW-11 to the three-pin connection block on
the rear of the SFS and on the CB (see the corresponding
manual).
waRNiNg
Prevent damage. Note the colour code of the cable
when connecting.
waRNiNg
Switch OFF the mains supply of the CB before
connecting the NCW-11.
4.2.3
Compressed air connection
The cleaning mechanism functions on compressed air with a
recommended working pressure of 400-500 kPa/4-5 bar (1600
- 2000 in. WG/60 - 75 psi). Always make sure that the
working pressure is between 400-500 kPa/4-5 bar (1600
- 2000 in. WG/60 - 75 psi). Preferably the pressure should be
at 450 kPa/4.5 bar (1800 in. WG/65 psi). If required, mount a
pressure reducing valve to prevent the safety valve from being
actuated.
waRNiNg
Prevent damage to the cleaning mechanism.
Make sure that the compressed air is free from oil
en moisture.
• Connect the compressed air hose to the cap nut (1/4" int.)
on the rear of the SFS.
5

usE

Fig. 5.1
cautiON!
Before use carefully read the safety instructions.
Determine based on the local regulations and the
welding process applied whether or not materials
can be recycled.
EN - 7

Publicité

Table des Matières
loading

Table des Matières