2. TECHNICAL REQUIREMENTS
2.4 Installation niche features:
StandPlus Series
A - area to be left clear for the anti-tipping brackets
Minimum Niche Height
2134 mm (84")
Minimum Niche Width
MS899 / FM36: 902 mm (35 1/2")
MS599 / FM24: 602 mm (23 3/4")
Door Swing Clearance
MS899 / FM36: 1470 mm (57 7/8")
MS599 / FM24: 1170 mm (46")
Door Opening Angle
105°
Width
MS899 / FM36: 899 mm (35 3/8")
MS599 / FM24: 599 mm (23 5/8")
Height
2120 mm (83 1/2") + 25 mm (1")
Depth with door
629 mm (24 3/4")
Minimum distance from the wall (hinge side)
MS899 / FM36: 230 mm (9")
MS599 / FM24: 160 mm (6 1/4")
Important!
If the units are to be installed inside a
niche or within an enclosed structure, it
is necessary to design a ventilation shaft
at the back of the niche to assure proper
ventilation at the back of the unit.
Cross-sectional chimney ventilation area
should equal 200cm² (31in²)
MS899 / FM36: 230 (9")
MS599 / FM24: 160 (6 ¼")
8
www.fhiaba.com · www.thevettagroup.com · Info Line 1-855-4-FHIABA (1-855-434-4222)
MS899 / FM36:
899
(35 ⅜")
MS599 /
FM24: 599
(23 ⅝")
140 (5 ½")
140 (5 ½")
A
A
MS899 / FM36: 902 (35 ½")
MS599 / FM24: 602 (23 ¾")
629 (24 ¾")
615 (24 ¼")
560 (22")
666 (26 ¼")
min 50 (2")