Step 1: Ventilation Requirements - Thermador PD30 Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

It is strongly recommended that a
suitable exhaust hood be installed
above the range. Downdraft
ventilation should not be used. The
table
below
indicates
Thermador hoods, by model
number, that are recommended
for use with all ranges.
1. Select Hood and
Blower Models:
For wall installations, the hood
width must, at a minimum,
equal the width of the range
cooking surface. Where space
permits, a hood larger in width
than the cooking surface may
be desirable for improved ven-
tilation performance.
For island installations, the
hood width should, at a mini-
mum, overhang the range
cooking surface by 3" on each
side.
RANGE WIDTH
30" RANGE
36" RANGE
48" RANGE
Notes: * For wall installations where adequate space is available, the installer or user may elect to
use a hood that is wider than the rangetop cooking surface. This may be particularly beneficial
for installations having a long duct run or when heavy usage of the grill is anticipated, in which
improved capturing of the cooking exhaust is desired.
** Thermador offers a choice of remote (VTR1030D or VTR1530D) or internal (VTN1030C)
blowers for use in wall installations.

Step 1: Ventilation Requirements

IMPORTANT:
Ventilation hoods and blowers are
designed for use with single wall
ducting. However, some local
the
building codes or inspectors may
require double wall ducting. Con-
sult local building codes and/or
local agencies, before starting, to
assure that hood and duct instal-
lation will meet local requirements.
Do not install a microwave oven /
ventilator combination above the
range, as these types of units do
not provide the proper ventilation
and are not suitable for use with
the range.
WALL INSTALLATION
HOOD*
PH30CS,
PHE30 / 36
HNW36YS
PH36CS / 42CS
PHE36 / 42
HNW36YS / 42YS
PH48CS / 54CS
PHE48 / 60
HNW48YS
BLOWER**
VTR1030D,
VTR1530D,
HNI42YS
or VTN1030C
HTNI42YS
VTR1030D
or VTR1530D
VTR1030D,
VTR1530D,
HNI42YS
or VTN1030C
HTNI42YS
VTR1030D
or VTR1530D
VTR1030D,
VTR1530D,
HTNI48YS / 54YS
or VTN1030C
HTNI48YS / 54YS
VTR1030D
or VTR1530D
2
2. Hood Placement:
For best smoke elimination,
the lower edge of the hood
should be installed 36" above
the range cooking surface.
(See Fig. 1).
If the hood contains any com-
bustible materials (i.e. a wood
covering), it must be a mini-
mum of 36" above the cooking
surface.
3. Consider Make-Up
Air:
Due to the high volume of ven-
tilation air, a source of outside
replacement air is recom-
mended. This is particularly
important for tightly sealed and
insulated homes.
A qualified heating and venti-
lating contractor should be
consulted.
ISLAND INSTALLATION
HOOD*
BLOWER**
VTR1030D,
or VTR1530D
VTR1030D,
or VTR1530D
VTR1530D