Thermador PD30 Instructions D'installation page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Do not install the 30" and 48" ranges such that the oven door is flush
with the cabinet face. A flush installation could result in damage to
the cabinets due to exposure to high heat.
FIG. 1 Cabinet Clearances
36" bottom of overhead
Hood to cooking sur-
face (36" min. if hood
contains combustible
18" Min.
materials
*35-3/8" Min. Range Height
with Leveling Legs fully
retracted
*36-3/4" Max. Range Height
with Leveling Legs fully
extended.
Step 2: Cabinet Preparation
:
CAUTION
For 30" Ranges
For 36" Ranges
For 48" Ranges
Min. Distance Between Overhead
Cabinets of Combustible Material
30" Range – 30"
36" Range – 36"
48" Range – 48"
.)
For Electrical and Gas Supply Zone,
see Figure 3A. Zone size and position
differ according to the model.
as defined in the "National Fuel Gas Code" (ANSI Z223.1,
Current Edition). *The range height is adjustable. The level of the
range top must be at the same level or above the countertop level.
}
30" or 36" Wide Hood
36" or 42" for Island
}
36" or 42" Wide Hood
42" or 48" for Island
}
48", 54, or 60" Wide Hood
48" or 54" for Island
13" Max.
}
Cabinet
Depth
combustible
Range width
®
30", 36" or 48"
material
Cooking
Surface
4
®
CAUTION:
3" Min. to
Figs. 2A, and 2B.
36" Min. to
®
side wall
combustible
,
material
(both sides)
from cooking
surface
See
,