GAS AND ELECTRIC SUPPLY ZONES:
FIG. 3A Gas & Electrical Supply Zone for Dual Fuel Ranges
Typical place-
ment shown.
Other placement
of Gas Supply
and Electrical
R e c e p t a c l e
within the Elec-
trical and Gas
Supply Zone is
acceptable.
NOTE:
If not already
present, install
gas
shut-off
valve in an eas-
ily accessible
location. Make
sure all users
know where and
how to shut off
the gas supply
to the range.
NOTE: The in-
staller should
inform the con-
sumer of the lo-
cation of the gas
shut-off valve.
Step 2: Cabinet Preparation
3/4" Flex Line
to Appliance
Gas
1/2"
Supply
NPT
Zone
2" Maximum Protru-
sion from Wall for
Gas Supply
Model
A
B
30"
8"
12"
36"
10-1/2"
15"
10-1/2"
48"
16-1/2"
16"
15-1/2"
NOTE: Any opening in the wall behind the
appliance and any opening in the floor under
the appliance must be sealed.
240 VAC Receptacle
(Shown) or Junction
Box
Centerline of
Electrical
Supply Zone
D
E
Floor
C
D
E
10"
6-1/2" 5-1/4"
6-1/2" 5-1/4"
6-1/2" 5-1/4"
6
The Dual Fuel ranges may be
connected to the power supply
with a range supply cord kit or by
hard-wiring to the power supply.
It is the responsibility of the in-
staller to provide the proper wir-
ing components (cord or conduit
and wires) and complete the elec-
trical connection as dictated by
local codes and ordinances, and/
or the National Electric Code. The
units must be properly grounded.
Refer to Step 6 for details.
The range must be connected
only to the type of gas for which
it is certified. If the range is to be
connected to propane gas, en-
sure that the propane gas supply
tank is equipped with its own high
pressure regulator in addition to
the pressure regulator supplied
with the range. (See Step 5.)