Télécharger Imprimer la page

Step 1: Ventilation Requirements - Thermador Professional PRO-GRAND Serie Instructions D'installation

Cuisinières mixtes

Publicité

Les langues disponibles

Les langues disponibles

Step 1: Ventilation Requirements

It is strongly recommended that a
suitable exhaust hood be installed
above the range. Downdraft
ventilation should not be used. The
table below indicates the
Thermador hoods, by model
number, that are recommended
for use with all ranges.
1. Select Hood and
Blower Models:
For wall installations, the hood
width must, at a minimum,
equal the width of the range
cooking surface. Where
space permits, a hood larger
in width than the cooking sur-
face may be desirable for im-
proved ventilation perfor-
mance.
For island installations, the
hood width should, at a mini-
mum, overhang the range
cooking surface by 3" on each
side.
RANGE WIDTH
30" RANGE
36" RANGE
48" RANGE
* For wall installations where adequate space is available, the installer or user may elect to
Notes:
use a hood that is wider than the range cooking surface. This may be particularly beneficial
for those cases, such as a long duct run or heavy usage of the grill, in which improved
capturing of the cooking exhaust is desired.
** Thermador offers a choice of remote (VTR1000Q or VTR1400Q) or in-hood (VTN1030C)
blowers for use in wall installations.
IMPORTANT:
Ventilation hoods and blowers are
designed for use with single wall
ducting. However, some local
building codes or inspectors may
require double wall ducting. Con-
sult local building codes and/or
local agencies, before starting, to
assure that hood and duct instal-
lation will meet local requirements.
Hood blower speeds should
be variable to reduce noise
and loss of heated or air con-
ditioned household air when
maximum ventilation is not
required. Normally, the maxi-
mum blower speed is only
required when using the grill.
WALL INSTALLATION
HOOD*
PH30CS,
VTR1000Q,
PHE30,36
VTR1400Q
OR VTN1030C
PH36CS, 42CS
VTR1000Q, VTR1400Q
PHE36,42
or VTN1030C
HNW36YS
VTR1000Q, VTR1400Q
HNW42 YS
VTR1000Q, VTR1400Q
PH48CS
VTR1000Q
PHE48,60
VTR1400Q
or VTN1030C
2. Hood Placement:
3 . Consider Make-Up Air:
BLOWER**
HOOD*
HTNI42YS
HNI42YS
HTNI42YS
HNI42YS
HTNI48YS
HNI48YS
HTNI54YS
HNI54YS
3
For best smoke elimination, the
lower edge of the hood should
be installed a minimum of 30" to
a maximum of 36" above the
range cooking surface. (See
Fig. 1).
If the hood contains any com-
bustible materials (i.e. a wood
covering), it must be a mini-
mum of 36" above the cooking
surface.
Due to the high volume of venti-
lation air, a source of outside
replacement air is recom-
mended. This is particularly im-
portant for tightly sealed and
insulated homes.
A qualified heating and ventilat-
ing contractor should be con-
sulted.
ISLAND INSTALLATION
BLOWER**
VTR1000Q,
VTR1400Q
VTR1000Q
VTR1400Q
VTR1400Q

Publicité