The heating light E
flashes slowly (lit 1
second, unlit 1 second).
The airing detector
does not react
- The ambient tem-
perature is diffe-
rent from the tem-
perature set on the
control knob C.
- Control knob C is
set to 19°C, a light
other
than
the
green one is lit.
If you do not succeed in solving your problem, contact your local installer and have the
details of your heater's references, the room's temperature and the programming system
(if any) to hand.
Your panel heater's potentiometer has deteriorated.
Contact your installer.
Your panel heater's environment may interfere with this function's ability to
react (e.g.: distance of the panel heater from the window, the external tem-
perature, the room's level of insulation, etc.). During airing, switch the cur-
sor A to Stand-by mode
If your ambient temperature, after 6 hours without adjusting the mode or
the setting, still differs from that set on the control knob, you can recalibra-
te your panel heater.
If a pilot wire kit or a carrier current interface is fixed to the
back of your panel heater, it is best to remove this first.
For recalibrating the heater, the temperature on the control
knob C must be set between 18°C and 23°C.
- While holding knob C, unlock the locking pin behind the knob with a flat-
bladed screwdriver.
- Turn the knob's numbered part C1 while hol-
ding the upper part C2 to match up the room's
temperature with that shown on the knob.
Take care not to turn the upper part C2: this would disrupt the
panel heater's controls.
- Relock the pin by pressing it down.
Any intentional damage (perforation, scratches) to the
absence detector's lens rescinds your appliance's war-
ranty.