Programmable Function Parameters; Maintenance And Servicing; Replacing The Jet Controller - Franke PRTR0009 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

13. Programmable function parameters

The optional remote control FAR-Order-No. 2000101087 offers the following
functions:
– Range can be set (3-20 cm)
– Turn-off delay can be set (0-10 s)
– Continuous flow can be switched between 3.5 min and 11 min.
– Fitting can be switched off
– Basic settings can be restored
– Test mode for simulation without water
– Automatic safety switch-off can be adjusted (2–210 s)
– Automatic flushing can be activated
Important!
Reflecting surfaces can influence the sensor. There is a risk of having permanent
reflections. The range must be reduced for installations on reflecting surfaces such
as stainless steel washbasins. If this is not sufficient, an additional base/spacing ring
is available (see

14. Maintenance and Servicing

Depending on the quality of the water, the local conditions and the rules and
regulations applicable on site, the fitting must be maintained and serviced at regular
intervals.
Perform maintenance on the following components:
• Jet controller (see
• Filters (see
Chapter
• Flow rate regulator (see
Properly use suitable cleaning agents that are not harmful to the fittings and rinse
with water after use. High-pressure cleaners must not be used for cleaning.
14.1 Push up the cleaning clip (a) in front of the sensor.
The fitting is in sleep mode.

15. Replacing the Jet Controller

15.1 Use the special wrench (a; FAR Order No. 2000105960) to unscrew and remove the
anti-theft jet controller (b).