environmental conditions. Mount the reflector in that
location.
• When applicable, connect the counter [6] (optional, not incl.)
to the output [5] using the 10m cable that comes with the
counter (PEM7D/C).
5.
Troubleshooting
When problems are encountered, refer to following overview
before contacting your local dealer:
• Check that the speaker is set to "CHIME" or "ALARM". "OFF"
= silent.
• Check that the timer and/or volume are not in the "min."
position.
• A red LED indicates proper alignment of the sensor and
reflector. If the LED is not lit, realign sensor and reflector.
Distance must be at least 50cm.
• Make sure the adapter is firmly connected to the speaker.
• Make sure the sensor is firmly connected to the input of the
speaker.
6.
Technical specifications
GENERAL
Nominal Detection Range
Supply Voltage
Light Source
Output
Ambient Temperature
SYSTEM
Power Supply
Total Current Consumption
Standby Current
SPEAKER
Supply Voltage
Speaker Output
Speaker Time
Adjustable Timer
Adjustable Volume
External Output
Use this device with original accessories only. Velleman
nv cannot be held responsible in the event of damage or
injury resulted from (incorrect) use of this device.
For more info concerning this product and the latest
version of this user manual, please visit our website
04.06.2010
PEM7D
7m
DC 9-15V
IR LED
NPN open collector
-20 to +50°C
AC to DC adapter 12V (included)
< 130mA
25mA
DC 9-15V
Chime / Off / Alarm selectable through
switch
± 1 second for chime, 30sec. for alarm
3-30sec. for alarm
yes (from 0 to max.)
NPN output (for external device e.g.
counter)
5
Rev. 01