Télécharger Imprimer la page

Nowy Styl eModel 2.0 Guide D'utilisation page 17

Masquer les pouces Voir aussi pour eModel 2.0:

Publicité

Les langues disponibles

Les langues disponibles

4. 
Error messages on the display
Symbol on the
display
Description
Short circuit on DRIVE 1
Short circuit on DRIVE 2
The cable connecting
DRIVE 1 is disconnected
The cable connecting
DRIVE 2 is disconnected
No measurable
movement
System protection /
system stop. The control-
ler monitors operation
time and maximum
temperature. One of
the two values has been
exceeded.
Collision detected
Overload on DRIVE 1
Overload on DRIVE 2
Loss of DRIVE
synchronisation
Loss of controller
synchronisation
Anti- collision
sensor error
Conflicting operations on
two different controllers.
Solution
Unplug the power supply. Check cables
connecting the column to the control
module for damage or connect the appro-
priate DRIVE to the appropriate socket. If
needed, perform system initialisation / first
start-up following the user manual.
Check the connection of the cables con-
necting the column to the control module
and perform a restart/first start-up.
Unplug the power supply. Check cables
connecting the column to the control
module for damage or connect the appro-
priate DRIVE to the appropriate socket. If
needed, perform system initialisation / first
start-up following the user manual.
Wait for the control module to cool down
and the display to turn off. The controller
will allow movement for 20 s. After a break
of 18 minutes, the workstation can be
adjusted again constantly for maximum
2 minutes.
Remove the obstacle
Maximum load has been exceeded. Reduce
the load by removing extra items from the
desk top. Level the workstation with glides.
Perform system initialisation / first start-up
following the user manual.
Reduce the load by removing extra items
from the desk top- if applicable.
Level the workstation with glides. Perform
system initialisation / first start-up follow-
ing the user manual.
Check if the cables are properly connected
to the controller and the mains. Perform
system initialisation / first start-up follow-
ing the user manual.
Height adjustment is possible but without
the anti-collision system. Check the exter-
nal anti-collision sensor for connection to
the control module.
Stop the operation of all elements con-
nected to the control module
EN 17

Publicité

loading