3. Malfunctions
Type of error
The workstation
does not move
The workstation performs
only a slow downward
movement
The workstation moves
slowly
The workstation makes
a short movement in one
direction
16 EN
Cause
Disconnected power cord
No connection or inaccurate
connection of electrical
components
No connection to the
control panel
Maximum load exceeded
Continuous adjustment
time exceeded
DRIVE damage
Control module damage
Drive damage
The control module forces
initialisation or reset
Maximum load exceeded
No connection or inaccurate
connection of electrical
components
Damaged drive
Solution
Connect the power cord,
check its connection to the
control module.
Check the component
connections to the control
module.
Connect the control panel to
the control module.
Reduce the load.
Reactivation will take place
after 3 minutes.
Note:
The maximum time of
uninterrupted operation of
the lifting mechanism is 2
minutes, followed by a break
in desk adjustment of at least
18 minutes.
Contact the Customer
Service.
Perform system initialisation
/ first start-up following the
user manual.
Reduce the load on the
desk top.
Check the component con-
nections to the
control module.
Contact the
Customer Service.

Publicité