Installation and Operating Instructions
EN
RD.. and VD.. – Roof fans
5.1
Type plate
Example:
Typ: VDD 315/4 EX
400V
3-
1380 1/min
II 2G c 11B + H
Motor: II 2G Ex e IIC T3 Gb
Herstelljahr: 2016
Character keys for fan type plate:
Manufacturer's address
CE mark
Execution:
VDD = Type name; Three phase current
315 = Size
/4 = pole
EX = Apparatus manufactured to 2014/34/EU
Rated voltage / Frequency
Rated speed / Rated current
Reference number
Serial number
Recorded rated output / Motor insulation class
Production code
max. ambient, air flow temperature at rated operation
Protection class / Weight
Marking of explosion-proof fans:
II 2G = Product category
c = Mechanical part of fan / Protection by constructional safety
IIB = Explosion subgroup
H
= Hydrogen
2
T3 = Temperature class
Type of protection of the motor = Classification
Year of manufacture
Art.-Nr. (Ref.no.), SNR (serial number) and PC (production code) number identify clearly the fan
5.2
Motor type plate
A copy of the motor type plate is located
Technical data are can be found on the motor type plate.
5.3
Accessories for explosion-proof fans
Information on explosion-proof accessories can be found on the Internet, the main catalogue or sales documents.
HELIOS VENTILATOREN
Lupfenstraße 8
78056 Villingen-Schwenningen Gerrnany
Art.Nr.: 07293 / 001
50 Hz
SNR: 000123
0,74A
0,32 kW
lso.CI. F
T3
2
in the cover of the terminal box.
8
CE:
Abb.6
PC 01625
TN 4o•c
IP 44 18,7 kg