Type Plate; Motor Type Plate; Accessories; Chapter 4. Function - Helios InlineVent KR EC Série Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation and Operating Instructions
CHAPTER 4
FUNCTION
m
NOTE
EC Rectangular Centrifugal Fans – InlineVent
3.1

Type plate

Example:
ä
ü
Æ
Key for fan type plate:
ò Manufacturer's address
ù Fan label:
CE = CE mark
ä Version:
KRW EC = Type designation
225/40/20 = Size
ë Item number
ö Production code / year of manuf.
The fan can be clearly identified by the ref. no., SNR (serial number) and PC (production code) numbers.

3.1.1 Motor type plate

Technical data about the motor can be found on the motor type plate!
3.2

Accessories

The use of accessories not offered or recommended by Helios is not permitted. Any potential damage is not
covered by warranty.
Flexible couplings
Multi-leaf damper for duct installation
Outside wall cover flap
Weather protection grille
Fitting
Counterflange
Vibration damper for tensile load
Vibration damper for pressure load
Duct sound damper
Speed-potentiometer
Three-step switch
Universal control system
Differential pressure/temperature controller
Flexible attenuator length
Warm water heater battery
Temp. control system for warm water heater battery
Electric heater battery
– with integrated temp. control
Temp. control system for EHR-R..
Duct air filter
4.0
Functional description SKR.. / KR.. EC
The rectangular centrifugal fans SKR.. / KR.. EC are variable speed controllable by means of a 0-10 V control voltage.
Suitable potentiometers (Type PU/A 10), three-step switches (Type SU/A) are available in the Helios accessory
range. Variable speed control is possible with a universal control system (Type EUR EC). Alternatively,
the electronic differential pressure/temperature controller EDR / ETR can be used..
m
Activation / deactivation:
EC fans can be frequently activated and deactivated via the 0-10 V control input or the release input
depending on the type. This is gentle on the electronics and ensures a long service life. Control via the
power supply (on/off) is not recommended. In general, there must be an interval of at least 120 seconds
between activation and deactivation.
m
In case of strong vibrations and/or noises, maintenance must be carried out by a specialist according to
chapter 1.4.
®
KR EC ... / SKR EC
ò
ù
ë
ö
Å
î
Ø
ü Nominal voltage or voltage range / Frequency
Å Rated current
î Input power
Ø max. flow medium temp. in rated operation
Æ Nominal speed
 Protection class / motor insulation class / cosine
 Installation and operating instructions/Print no.
VS..
JVK
VK..
WSG..
FSK..
GF
SDZ
SDD
KSD..
PU/A 10
SU/A
EUR EC
EDR/ETR
FSD..
WHR
WHST.. / WHS HE..
EHR-R..
EHR-R..TR
EHS
KLF.. G4
KLF.. F7
5
EN
Fig.3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Inlinevent skr ec sérieInlinevent krw ec 180/30/15Inlinevent krw ec 225/40/20Inlinevent krw ec 315/50/25Inlinevent krw ec 315/50/25 bInlinevent krw ec 355/60/30 ... Afficher tout

Table des Matières