Electrical Connection - Schulthess proLine D 200 Notice D'installation

Masquer les pouces Voir aussi pour proLine D 200:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Warning
If additional appliances are operated in the room
where the appliance is installed or in adjoining rooms,
such as gas-fired heating systems, gas-fired in-
stantaneous water heaters, coal-fired ovens with
a chimney connection or open fireplaces, a partial
vacuum may be caused leading to the sucking back of
the exhaust gases .
Do not route the exhaust pipe into a fireplace that is
connected to devices such as gas or coal fired stoves
and ovens, or gas room heaters .
Condensation dis charge
At the lowest point in the exhaust air duct, you are
recommended to fit a «condensation water collector»
(proprietary) or a condensation dis charge hole of
about ø = 3 mm .
40
EN

Electrical connection

Notice
Connection of the appliance to the power supply must
be carried out by a specialised electrician .
When the machine is operated for the first time
the
Data
and
Time
settings are to be checked and
if necessary, set correctly (see
Settings
in the operating instructions) .
Perform the electrical connection according to the
regulations or provisions made by the local electricity
authority and utility companies .
Approval for fixed connection, all-pole disconnectable
by a main switch .
The protective conductor connection is to be de-
signed in such a way that the protective wire only
breaks in the case of excessive tensile load after all
active (current- carrying) lines have been isolated .
In rooms in which fault-current protective switches
are required or recommended in order to increase
safety, the release current must be 30 mA .
Use a fault-current protective switch with the
symbol .
The motor is provided with overload protection .
The switch can be locked in the position OFF .
Mains cable
The appliance is delivered without mains supply cable
for connection to 3-phase alternating current with
neutral conductor (400 V 3 N ~) .
Warning
Risk of injury owing to current carrying or
rotating machine parts
Ensure that all the dismantled housing parts are re-fas-
tened after erecting and connecting the machine .
Risk of electric shock and risk of fire!
No extension cables, no multi-coupling and no plug-in,
mobile time switches may be used .
Do not use plug-in, mobile timer switches . The ma-
chine may not be connected via an external switching
mechanism, which regularly switches the machine on
and off (e .g . timer switch) .
Settings / Menu

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Proline d 325

Table des Matières