• If you have an outlet to the outside, your cooker hood can be connected by means of
an extraction duct (enamel, aluminium, flexible pipe or non-flammable material with
an inner diameter of 150-120mm).
i. Attach the expansion pipe to the outside outlet.
NOTICE:
• K eep expansion pipes short and straight.
• D o not reduce the size of the expansion pipe.
• W hen using an expansion pipe, always install the pipe pulled out to minimize
pressure loss.
• Failure to observe these instructions will reduce the performance and increases
noise levels of the cooker hood.
• D o not connect the ducting system of the cooker hood to any existing ventilation
system that is being used for any other appliance.
• T he angle of the bend of the expansion pipe should not be less than 120º.