26 | English
multiple active measuring tools are found, select the appro-
priate measuring tool. A connection will be established auto-
matically if only one active measuring tool is found.
The connection is established as soon as the Bluetooth® in-
dicator (9) lights up.
The Bluetooth® connection may be interrupted if the dis-
tance between the measuring tool and the mobile terminal
device is too great or is blocked, and if there are any sources
of electromagnetic interference. Should this occur, the
Bluetooth® indicator (9) will flash.
Switching off Bluetooth®
To switch off Bluetooth® for remote control, press the
Bluetooth® button (10) or switch off the measuring tool.
Accuracy Check of the Measuring Tool
Influences on Accuracy
The largest influence is exerted by the ambient temperature.
In particular, temperature differences that occur from the
ground upwards can refract the laser beam.
Since the temperature stratification is greatest at ground
level, you should always mount the measuring tool on a tri-
pod for measuring distances of 20 m or more. In addition,
position the measuring tool in the centre of the work surface,
wherever this is possible.
In addition to external influences, device-specific influences
(e.g. falls or heavy impacts) can also lead to deviations. For
this reason, check the levelling accuracy each time before
beginning work.
First check the height accuracy and levelling accuracy of the
horizontal laser line, then the levelling accuracy of the ver-
tical laser line and the plumb accuracy.
Should the measuring tool exceed the maximum deviation
during one of the tests, please have it repaired by a Bosch
after-sales service.
Checking the Height Accuracy of the Horizontal Line
For this check, you will need a free measuring distance of
5 m on firm ground between two walls (designated A and B).
– Mount the measuring tool close to wall A on a tripod, or
place it on a firm, level surface. Switch on the measuring
tool. Select cross-line mode with automatic levelling.
A
5 m
– Aim the laser at the closer wall A and allow the measuring
tool to level in. Mark the middle of the point at which the
laser lines cross on the wall (point I).
1 609 92A 4HG | (12.11.2020)
A
180°
– Turn the measuring tool 180°, allow it to level in and mark
the point where the laser lines cross on the opposite wall
B (point Ⅱ).
– Position the measuring tool – without rotating it – close to
wall B, switch it on and allow it to level in.
A
– Align the height of the measuring tool (using the tripod or
by placing objects underneath as required) so that the
point where the laser lines cross exactly hits the previ-
ously marked point Ⅱ on wall B.
A
d
– Turn the measuring tool 180° without adjusting the
height. Aim it at wall A such that the vertical laser line runs
B
through the already marked point Ⅰ. Allow the measuring
tool to level in and mark the point where the laser lines
cross on wall A (point Ⅲ).
– The discrepancy d between the two marked points Ⅰ and
Ⅲ on wall A reveals the actual height deviation of the
measuring tool.
The maximum permitted deviation on the measuring dis-
tance of 2 × 5 m = 10 m is as follows:
10 m × ±0.3 mm/m = ±3 mm. The discrepancy d between
points Ⅰ and Ⅲ must therefore amount to no more than
3 mm.
B
B
B
180°
Bosch Power Tools

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gcl 2-50 cg professional

Table des Matières