After Sale Service; Accessories - SATA HRS Mode D'emploi

Masquer les pouces Voir aussi pour HRS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 169
Operating Instructions for SATA HRS
US
Malfunction
Material not flowing
Atomization too coarse Inlet pressure too low.
No material or insuffi-
cient material at nozzle

13. After Sale Service

Please contact your SATA dealer for accessories, spare parts and techni-
cal support.

14. Accessories

Art. No. Description
16071
Rigid door wand (steel) 43.3" long, Ø 0.3", with radial
nozzle 360° radial fan, spraying forward
196832 Door wand (steel) 5.9" long, Ø 0.3", with radial nozzle
360° radial fan, spraying forward, with flexible guide
hose 39.4"
482
Cause
Pressure not supplied
to pressure cup.
Material viscosity is
too high.
Wand diameter is too
small.
Wand tip is soiled.
Corrective action
Connect to com-
pressed air circuit.
Remove check valve
[1-18], clean and, if
necessary, replace
(see 11.3).
Remove inlet valve
[3-9], clean and, if
necessary, replace
(see 10.4 and 11.4).
Remove quick connect
coupling [2-4], clean
and, if necessary, re-
place (see 10.1).
Increase inlet pres-
sure.
Use larger diameter
wand.
Clean wand tip (see
11.2).
Quan-
tity
1 ea.
1 ea.

Publicité

Table des Matières
loading

Table des Matières