Translated copy of the original Italian text
• Checking the connection to the protective
conductor
Frequency
Once a year
Additional description
Ensure that the machine is connected to the
protective conductor and that the earth wire
inside the power supply cable is not broken.
Competence for the task
Maintenance technician
• Checking the earth connection
Frequency
Once a year
Additional description
Check the efficiency of the system's earth
connection.
Competence for the task
Maintenance technician
• Unscheduled maintenance
Frequency
-
Additional description
-
Competence for the task
TECNA s.p.a.
8.2
Cleaning the welding machine
CAUTION
Do not clean the welding machine with
sprayed water as this could penetrate
inside it; also avoid using strong solvents,
thinners or petrol, which can damage the
paint and plastic parts on the machine.
8.3
Cleaning the electrodes
DANGER
Before
performing
disconnect the air supply from the gun.
The electrodes can be cleaned with a fine-grained
abrasive tool.
Replace the electrodes if they are excessively worn.
8.4
(See attached image A5)
To replace the electrodes, follow the instructions given
below:
• Disconnect the compressed air supply hose (1).
• Activate the "NO WELD" function from the operator
• Remove and replace the electrodes (2), taking care
• Disconnect the compressed air supply hose (1).
• Lightly press the trigger (4) to close the electrodes
• Activate the "NO WELD" function from the operator
• After replacing the electrodes, the calibration
any
operation,
EN-16
Replacing the electrodes
DANGER
Before
performing
disconnect the air supply from the gun.
panel; this stops the coolant from circulating;
not to damage the cone on the electrode holder (3).
WARNING
The electrode can be extracted with the
special extractor supplied.
To facilitate the extraction of the electrode
and prevent seizure of the cone, high
conductivity grease can be used, like that
provided in the supply.
Do not use sealants to eliminate water
leaks from the tapered socket on the
electrodes.
until they lock into position;
panel; this stops the coolant from circulating;
procedure must be performed from the operator
panel.
WARNING
For more information, consult the
operator panel manual supplied as a an
attachment.