Balluff BMF 203K-H Série Notice D'utilisation page 45

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57
BMF 203K-H- _ _ -C-A _ -... / BMF 235K-H- _ _ -C-A _ -...
Magnetic Field Sensors
7
IO-Link (continued)
7.5
Parameter data
Index
Subindex
Switchpoint parameters (see section 7.5.1)
0x003A (58)
0
0x003B (59)
0
0x003C (60)
0, 1, 2
0x003D (61)
0, 1, 2, 3
0x003E (62)
0, 1, 2
0x003F (63)
0, 1, 2, 3
0x4000 (16384)
0, 1, 2
0x4001 (16385)
0, 1, 2, 3
0x4002 (16386)
0, 1, 2
0x4003 (16387)
0, 1, 2, 3
0x4004 (16388)
0, 1, 2
0x4005 (16389)
0, 1, 2, 3
0x4006 (16390)
0, 1, 2
0x4007 (16391)
0, 1, 2, 3
0x4008 (16392)
0, 1, 2
0x4009 (16393)
0, 1, 2, 3
0x400A (16394) 0, 1, 2
0x400B (16395) 0, 1, 2, 3
System parameters
0x0003 (3)
0, 1, 2, 3, 4, 5
0x000C (12)
0
0x000D (13)
0, 1, 2, 3, 4
0x000E (14)
0, 1, 2, 3
Tab. 7-4:
Parameter data of IO-Link interface
7.5.1
Switchpoint configuration
The BMF has 8 integrated switching signals, each
described by two parameters (Set Point Value and
Switch Point Configuration).
Switchpoints can only be taught using the teach-in
procedure. The switchpoint width depends on the taught
position and is not constant over the detection area.
Direction
Taught position
BDCx
Switchpoint Width
Fig. 7-1:
Switchpoint width
www.balluff.com
Parameter
Teach-In Channel
Teach-in Status
Set Point Value BDC1
Switch Point Configuration BDC1
Set Point Value BDC2
Switch Point Configuration BDC2
Set Point Value BDC3
Switch Point Configuration BDC3
Set Point Value BDC4
Switch Point Configuration BDC4
Set Point Value BDC5
Switch Point Configuration BDC5
Set Point Value BDC6
Switch Point Configuration BDC6
Set Point Value BDC7
Switch Point Configuration BDC7
Set Point Value BDC8
Switch Point Configuration BDC8
(see Section 7.5.3)
(see Section 7.5.4)
(see Section 7.5.5)
(see Section 7.5.6)
S
Size
Access
Data storage
1 byte
Read/Write
1 byte
Read Only
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
4 bytes
Read/Write
42 bytes
Read/Write
2 bytes
Read/Write
10 bytes
Read Only
9 bytes
Read Only
english
X
X
X
X
X
X
X
X
X
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bmf 235k-h série

Table des Matières