Technical data
Rated input voltage:
Output power at 25 °C for
10 minutes:
Peak output power:
Output voltage:
Output frequency:
Idle current consumption:
Standby current
consumption:
Input voltage range:
Efficiency up to:
Bypass relay:
Ambient temperature for
operation:
Ambient temperature for
storage
Priority circuit:
Dimensions W x D x H:
Weight:
34
MSI1812
200 – 240 Vw pure sine wave (THD < 3%)
+40 °C to +60 °C (reduced power)
see fig. e, page 9 see fig. e, page 9
5.5 kg
MSI1812T
12 Vg
1800 W
3200 W
50 or 60 Hz
2.1 A
0.5 A
10.5 V – 16 V
90 %
25 A/277 Vw
–20 °C to +40 °C
–30°C to +70°C
230 V-input fuse: 10 A
Switchover time of bypass relay: < 30 ms
6 kg
SinePower
MSI1812TOE
see fig. f,
page 10
6 kg
EN