Sony VPL-FX50 Mode D'emploi page 33

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Others
Symptom
The LAMP/COVER indicator
flashes.
The LAMP/COVER indicator
lights up.
The TEMP/FAN indicator
flashes.
The TEMP/FAN indicator
lights up.
Both LAMP/COVER and
TEMP/FAN indicators light up.
The INPUT C window does
not appear, or INPUT C
cannot be selected.
The menu display does not
appear even when you press
the MENU key on the Remote
Commander.
Warning messages
Use the list below to check the meaning of the messages displayed on the screen.
Message
High temp.!
Lamp off in 1 min.
Frequency is out of range!
Please check INPUT-A
setting.
Please replace the LAMP.
Backup Battery Very Low
Caution messages
Use the list below to check the meaning of the messages displayed on the screen.
Message
NO INPUT
Not applicable!
LENS CONTROL is locked!
Do you wish to unlock?
Cause
The lamp cover is detached or the air
filter is not inserted securely.
The lamp has reached the end of its life.
The lamp becomes a high temperature.
The fan is broken.
The internal temperature is unusually
high.
The electric system failed.
INPUT C FUNC. is set to OFF.
The PJ/NETWORK select switch on the
Remote Commander is set to
NETWORK.
Meaning
Internal temperature is too high.
This input signal cannot be projected as
the frequency is out of the acceptable
range of the projector.
The resolution setting of the output
signal of a computer is too high.
You have input RGB signal from the
computer when INPUT-A in the SET
SETTING menu is set to COMPONENT
or VIDEO GBR.
It is time to replace the lamp.
A backup battery for the network is
exhausted.
Meaning
No input signal
You have pressed the wrong key.
LENS CONTROL in the INSTALL
SETTING menu is set to OFF.
Remedy
Attach the lamp cover or insert the air filter
securely (see pages 30 (GB) and 31 (GB)) .
Replace the lamp (see page 30 (GB)).
Wait for 120 seconds to cool down the lamp and
turn on the power again (see page 20 (GB)) .
Consult with qualified Sony personnel.
Check to see if nothing is blocking the ventilation
holes.
Consult with qualified Sony personnel.
Set INPUT C FUNC. in the INSTALL SETTING
menu to ON (see page 27 (GB)) .
Set the PJ/NETWORK select switch to PJ, then
press the MENU key.
Remedy
Turn off the power.
Check to see if nothing is blocking the ventilation
holes.
Input a signal that is within the range of the
frequency.
Set the setting of output to the XGA (see page 15
(GB)).
Set INPUT-A correctly (see page 26 (GB)) .
Please replace the lamp.
Consult with qualified Sony personnel.
Remedy
Check connections (see pages 15 (GB) to 17 (GB)) .
Press the appropriate key.
Select YES, or set LENS CONTROL in the
INSTALL SETTING menu to ON, according to
your requirement.
Troubleshooting
33
(GB)

Publicité

Table des Matières
loading

Table des Matières