Recirculation Cover (part of Recirculation Kit)
A
A. 18
B. 3
31
C.
/
11
Cabinet Dimensions
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
NOTES:
Cabinet opening dimensions shown are for 25" (64 cm)
■
countertop depth, 24" (61 cm) base cabinet depth, and 36"
(91 cm) countertop height. Dimensions must be met in order
to ensure a flush fit to the back wall.
For clarification, all cabinet illustrations are shown with the
■
door and front panel removed.
Countertop Cutout and Clearances
C
K
A. 36" (91.4 cm)
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform
and bottom of uncovered wood or metal cabinet (24" [61 cm]
minimum clearance if bottom of wood or metal cabinet is covered by
not less than
/
" [0.6 cm] flame-retardant millboard covered with not
1
4
less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, or
0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33 cm) recommended upper-cabinet depth
E. 2
/
" (6.8 cm)
11
16
F. 20
/
" (53.0 cm)
7
8
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop
within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom
of countertop
I. Junction box or outlet; maximum 24" (61 cm) from centerline
of cabinet
J. 35
/
" (90.0 cm)
7
16
K. 2
/
" (6.4 cm) minimum distance to nearest left- and right-side
1
2
combustible surface above cooktop
L. 1
/
" (3.7 cm) minimum clearance between back wall and countertop
15
32
NOTE: After making the countertop cutout, some installations
may require notching down the base cabinet sidewalls to clear
the cooktop base. To avoid this modification, use a base cabinet
with sidewalls wider than the cutout.
B
/
" (47.0 cm)
1
2
/
" (10.1 cm)
32
" (1.7 cm)
16
A
D
B
L
F
G
E
H
I
J
Cutout Dimensions
C
NOTE: All dimensions for cabinet cutouts are to be located
from the centerline/center point of the countertop cutout.
Style 1 – Cabinet Cutouts for Vented Installations
Cabinet cutout areas are for venting out of the right-hand side of
the blower motor assembly to the back or through the floor. All
cutouts are to be located from the centerline/center point of the
countertop cutout.
11"
(280 mm)
/
"
3
8
(10 mm)
A. The vent supply area in back of the cabinet is for venting out of the
back of the cabinet, using a 3
and a flat 90° elbow.
B. The vent supply area in the cabinet floor is for venting through the
K
bottom of the cabinet using 3
and a 90° elbow.
NOTE: Gray areas are references for ducting locations.
Centerline/center point
of countertop cutout
17"
(439 mm)
A
4" min.
(101 mm)
B
/
" min.
5
16
(8 mm)
Centerline/center point
of countertop cutout
/
" x 10" (8.3 cm x 25.4 cm) vent duct
1
4
/
" x 10" (8.3 cm x 25.4 cm) vent duct
1
4
5