Style 2 – Recirculation to the Front
1. Using a T20
TORX
driver, remove the 2 screws and cover
®
®
from the electrical junction box on the front panel of the
blower motor assembly housing and set aside.
2. Using a T20
TORX
driver, remove the 4 screws and the
®
®
electrical junction box from the mounting bracket and
set aside.
NOTE: Do not remove any electrical connections.
C
B
A
E
A. Cover – electrical junction box
B. Electrical junction box
C. Mounting bracket – electrical junction box
D. Blower motor assembly housing
E. Screws (6)
3. Using a T20
TORX
driver, remove the 11 screws and cover
®
®
panel from the front blower motor assembly housing.
A
B
C
A. Blower motor assembly housing
B. Cover panel
C. Screws (11 for each plate)
D. Panel and motor assembly
4. Using a T20
TORX
driver, remove the 3 screws and the
®
®
electrical junction box mounting bracket from panel and
set aside.
5. Disconnect the 9-pin blower motor electrical connector.
6. Using a T20
TORX
driver, remove the 11 screws that attach
®
®
the panel and motor assembly to the right side of the blower
motor assembly housing. Remove the panel and motor
assembly from the blower motor assembly housing.
7. Assemble the electrical box bracket to the front panel using
the 3 screws and tighten.
C
B
A
E
A. Blower motor assembly housing
B. Mounting bracket – electrical junction box
C. Electrical junction box
D. Cover – electrical junction box
E. Screws (6)
12
D
D
C
D
8. Reassemble the panel and motor assembly into the front of
the blower motor assembly housing. Install the 11 screws
and tighten.
A
B
C
A. Blower motor assembly housing
B. Panel and blower motor assembly
C. Screws (22)
D. Front panel
9. Reconnect the 9-pin blower motor electrical connector.
10. Reassemble the panel to the right side of the blower motor
assembly housing. Install the 11 screws and tighten.
11. Reassemble the electrical box to the bracket using the
4 screws and tighten.
12. Assemble the 2-piece telescoping rectangular vertical duct
to the blower motor assembly top duct extension. Secure
with screw and metal duct tape.
A. Telescoping rectangular duct (2 pieces)
B. M4 x 9.5 mm screw
C. Blower motor assembly top duct extension
Style 3 - Vented or Recirculation to the Left
1. Using a T20
TORX
driver, remove the 11 screws and panel
®
®
from the left side of the blower motor assembly housing and
set aside.
2. Disconnect the 9-pin blower motor electrical connector.
D
C
A
B
C