Weller WX 1 Mode D'emploi page 39

Masquer les pouces Voir aussi pour WX 1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 53
Parameter menu
Robot output
Note
If the robot is at working
temperature, the display will
show – ok –. Not available
with Zero Smog + Stop&Go
Vacuum pre-feed (WXD2 only)
Vacuum run-on (WXD2 only)
The robot output is on the back of the device.
Password (lock function):
WX1: OFF – On – ZeroSmog – Stop&Go
WX2/ WXD2: Off – left – right – left & right – ZeroSmog – Stop&Go
Option
Description
left
left tool channel (factory setting)
right
right tool channel
left & right
both tool channels
ZeroSmog
The rear floating switching output is closed when a
tool is in use. Selected Zero Smog extraction sys-
tems can be connected using an optional adaptor
(WX HUB). The rear RS 232 port continues to be
functional.
Switching output is open in the Standby, Auto Off
or Off positions, or if no tool is inserted.
Stop&Go
The rear RS232 port is used to drive an optotrans-
mitter so that a KHE/KHP can be activated via an
optical fibre.
The output is activated when a tool is used. In
addition, the floating switched output is closed.
The output is off in the Standby, Auto Off or Off
positions, or if no tool is inserted.
In order to prevent the pump from starting prematurely or to ensure
a defined soldering-joint preheating time, it is possible to set an ON
delay.
Option
Description
0 sec
OFF: vacuum pre-feed function is OFF (factory
setting)
1-10 sec
ON: vacuum pre-feed time, individually
To prevent the desoldering iron from becoming clogged, it is possible
to set a vacuum run-on time.
Option
Description
0 sec
OFF: vacuum run-on function is OFF (factory
setting)
1-10 sec
ON: vacuum run-on time, individually adjustable
Menu access
Station parameters
Menu access
Station parameters
Menu access
Station parameters
37

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wx 2Wxd 2Wxa 2

Table des Matières