Parameter menu
Max. hot air duration WXHAP
Offset (temperature offset)
Control response
Button lock WXHAP
34
Limit the on-time of the hot air tool (WXHAP).
The on-time of the hot air flow of the WXHAP can be limited in incre-
ments of 1 to between 0 and 60 sec. The set time is then identical for
both channels. The factory default is 0 s („OFF"), i.e. air flows only
as long as the button on the hot air tool or the optional footswitch is
pressed.
Option
Description
OFF
No duration defined (factory setting)
1-60 s
Individually adjustable
The actual soldering-tip temperature can be adapted by entering a
temperature offset around ± 40 °C (± 72 °F).
The function determines the heating characteristics of the soldering
tool to achieve the set tool temperature.
Option
Description
standard
adapted (medium) heating (factory setting)
soft
slow heating
aggres-
rapid heating
sive
This function can be used to adjust the factory button presets of the
WXAHP tool.
Option Description
ON
The WXHAP is switched
on the first time the button
is pressed and switched off
the next time the button is
pressed.
OFF