Technical Data; Operating Conditions; Application Conditions; Rating Plate - Burkert 6212 Manuel D'utilisation

Masquer les pouces Voir aussi pour 6212:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.

Technical daTa

6.1.

Operating conditions

The following values* are indicated on the rating
plate:
Voltage
(tolerance ±10 %) / current type
Coil power consumption
(active power in W - at operating temperature)
Pressure range
Housing material
brass (MS) or stainless steel (VA)
Seal material
FKM, EPDM, NBR
* see description of rating plate below
Operating principle 2/2-way valve:
A (NC)
B (NO)
Protection class: IP65 in accordance with DIN EN 60529
/ IEC 60529 with device socket
english
12
Important information concerning functional reliability
during continuous operation!
If switched off for a long period, at least 1-2 activations
per day are recommended.
Service life
High switching frequency and high pressures reduce the
service life.
6.3.
conformity
CE mark conforms to EMC Directive 2004/108/EEC only if
cables, plugs and sockets connected correctly.
6.4.

rating plate

Fig. 1:
Location of the rating plate
english
14
A
P
Rating plate
6.2.

application conditions

Allowable temperatures
Ambient temperature:
max. +55 °C
Heat-radiating energy sources must not additionally heat
the unit.
Permitted medium temperature depending on seal
material:
FKM
0 ... +50 °C
NBR
0 ... +50 °C
EPDM
-10 ... +50 °C
Permitted medium depending on seal material:
Seal material
FKM
Per-Solutions, oil, fat, diluted acids
NBR
Neutral medium, such as compressed
air, water, hydraulic oil
EPDM
Oil and fat free medium, diluted base
Duty cycle:
100% continuous rating (operating with
24 V/DC),
40 %, 20 min. intermittent duty (operating
with 110-120 V/UC, 230-240 V/UC)
6.4.1.
description of the rating plate
Example:
Orifice
Operating
prinziple
Type
6212 A 13,0 FKM MS
G1/2
230-240V AC/DC
00138961
Id.-Number
Manufacturer code
Voltage, Power consumption
Connection thread, Nominal
pressure
Fig. 2:
Rating plate - Example
Type 6212
Permitted medium
english
Seal material
Housing material
P N0,2 - 10bar
4W
W11 ML
english
13
15

Publicité