Safety Instructions; Mains Connection - Milwaukee M12-18 FC Notice Originale

Masquer les pouces Voir aussi pour M12-18 FC:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
TECHNICAL DATA
BATTERY CHARGER
Voltage range ..........................................................................................
Quick charge current ...............................................................................
Battery charging time with 12 V / 1.5 Ah..................................................
Battery charging time with 18 V / 5.0 Ah..................................................
Battery charging time with 18 V / 6.0 Ah..................................................
Battery charging time with 18 V / 9.0 Ah..................................................
Weight according EPTA-Procedure 01/2003 ...........................................
Recommended ambient charging temperature .......................................
WARNING! Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric
shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.

SAFETY INSTRUCTIONS

Do not dispose of used battery packs in the household refuse or by
burning them. Milwaukee Distributors off er to retrieve old batteries to
protect our environment.
Only the following battery packs can be charged with this charger:
Battery Cat.
Cell Type
DC Volts
Capacity
No.
M12B
Li-Ion
12
≤ 1.5 Ah
M12BX
Li-Ion
12
≤ 3.0 Ah
M12B2
Li-Ion
12
≤ 2.0 Ah
M12B3
Li-Ion
12
≤ 3.0 Ah
M12B4
Li-Ion
12
≤ 4.0 Ah
M12B6
Li-Ion
12
≤ 6.0 Ah
M14B
Li-Ion
14.4
≤ 1.5 Ah
M14BX
Li-Ion
14.4
≤ 3.0 Ah
M14B4
Li-Ion
14.4
≤ 4.0 Ah
M18B
Li-Ion
18
≤ 1.5 Ah
M18BX
Li-Ion
18
≤ 3.0 Ah
M18B2
Li-Ion
18
≤ 2.0 Ah
M18B4
Li-Ion
18
≤ 4.0 Ah
M18B5
Li-Ion
18
≤ 5.0 Ah
M18B6
Li-Ion
18
≤ 6.0 Ah
M18B9
Li-Ion
18
≤ 9.0 Ah
Do not try to charge non-rechargeable batteries with this charger.
Do not store the battery pack together with metal objects (short circuit
risk).
No metal parts must be allowed to enter the battery section of the
charger (short circuit risk).
Never break open battery packs or chargers and store only in dry
rooms. Keep dry at all times.
The battery clamps of the charger are fed by the mains supply. Do not
touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new one.
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
This appliance is not intended to be used
or cleaned by persons with reduced
physical, sensory or mental capabilities,
or lack of experience or knowledge,
unless they have been given instructions
concerning the safe use of the appliance
by a person legally responsible for their
safety. They should be supervised whilst
8
ENGLISH
M12-18 FC
...... 12 V, 14,4 V, 18 V
..............................6 A
............................20 min
............................59 min
............................90 min
............................90 min
..........................703 g
....................... +5...+40 °C
using the appliance. Children shall not
use, clean or play with this appliance,
which when not in use should be secured
out of their reach.
Warning! To reduce the risk of fi re, personal injury, and product
damage due to a short circuit, never immerse your tool, battery pack or
charger in fl uid or allow a fl uid to fl ow inside them. Corrosive or
conductive fl uids, such as seawater, certain industrial chemicals, and
bleach or bleach containing products, etc., can cause a short circuit.
Cell No.
SPECIFIED CONDITIONS OF USE
This charger charges 12V, 14.4V and18V Milwaukee Li-Ion battery
3
packs.
2 x 3
Do not use this product in any other way as stated for normal use.
3
3

MAINS CONNECTION

2 x 3
Connect only to single-phase AC current and only to the system
2 x 3
voltage indicated on the rating plate. It is also possible to connect to
4
sockets without an earthing contact as the design conforms to safety
2 x 4
class II.
2 x 4
LI-ION BATTERIES
5
2 x 5
The rechargeable batteries are partially charged. The LED on the
battery indicates the state of charge.
5
2 x 5
If it is not used for long periods, the rechargeable battery will switch to
the non-operative state.
2 x 5
2 x 5
When fully discharged the rechargeable battery switches off
automatically (depth discharge not possible).
3 x 5
Under extreme circumstances, the internal temperature of the battery
could become to high. If this happens, the battery will shut down.
Place the battery on the charger to charge and reset it.
The state of charge can be read by pressing the button on the
rechargeable battery. The battery can be left in the electric tool while
the reading is taken but it must be switched off at least one minute
beforehand (otherwise the display will be inaccurate). The number of
LEDs illuminated indicates the state of charge. A fl ashing LED
indicates a max. power reserve of 10%.
As a general principle, if the electric tool should fail to work after
inserting the rechargeable battery, then the battery should be plugged
into the charger. The displays on the battery and charger will then
provide information about the condition of the battery.
In low temperatures work may continue at reduced output.
CHARACTERISTICS
After inserting the battery into the reception of the charger the battery
will automatically be charged (red control lamp is illuminated
continuously)
When a hot or cold battery pack is inserted into the charger (fl ashing
red lamp), charging will begin automatically once the battery reaches
the correct charging temperature (0°C...65°C). The max. charging
current is fl owing when the temperature of the Li-Ion-battery is between
0°C and 65°C.
The battery's charging time is between 1 min and 20 min (at 1,5 Ah),
depending on the state of discharge.
Once the battery is fully charged, the LED on the charger changes
from red to green.
Remove the battery pack from the tool for charging when convenient
for you and your job. Milwaukee batteries do not develop a memory
when charged after only a partial discharge. It is not necessary to run
down the battery pack before placing it on the charger.
As a general practice, it is best to unplug battery chargers and remove
batteries when not in use. No battery pack damage will occur,
however, if the charger and battery pack are left plugged in.
If both LEDs fl ash alternately then the rechargeable battery is either
not fully pushed in or there is a fault with the battery or charger. Take
the charger and battery out of use immediately for safety reasons and
have them inspected by a Milwaukee customer service centre.
Both 12V and 14.4/18V battery packs can be inserted into the charger
at the same time, but they will be charged one after the other. The fi rst
battery pack to be inserted will be the fi rst one to be charged. The red
LED for the second battery pack will fl ash slowly to indicate that the
charging process has not begun yet.
LIGHT INDICATORS
Continuous red
Charging
Slow fl ashing green
Approaching full charge
Continuous green
Charging is complete
Battery is too hot/cold - Charging
Fast fl ashing red
will begin when battery reaches
correct charging temperature
Battery charge is pending -
Slow fl ashing red
Charging will begin when the fi rst
pack is fully charged
Flashing red/green
Damaged or faulty battery pack
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods Legislation
requirements.
Transportation of those batteries has to be done in accordance with
local, national and international provisions and regulations.
• The user can transport the batteries by road without further
requirements.
• Commercial transport of Lithium-Ion batteries by third parties is
subject to Dangerous Goods regulations. Transport preparation and
transport are exclusively to be carried out by appropriately trained
persons and the process has to be accompanied by corresponding
experts.
When transporting batteries:
• Ensure that battery contact terminals are protected and insulated to
prevent short circuit.
• Ensure that battery pack is secured against movement within
packaging.
• Do not transport batteries that are cracked or leak.
Check with forwarding company for further advice
MAINTENANCE
If the supply cord of this appliance is damaged, it must only be
replaced by a repair shop appointed by the manufacturer, because
special purpose tools are required
Use only Milwaukee accessories and Milwaukee spare parts. Should
components need to be replaced which have not been described,
please contact one of our Milwaukee service agents (see our list of
guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please state
the Article No. as well as the machine type printed on the label and
order the drawing at your local service agents or directly at: Techtronic
Industries GmbH, Max-Eyth-Straße 10, 71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before starting the
machine.
Do not burn used battery packs.
Never charge a damaged battery pack.
Replace with a new one.
Do not dispose electric tools, batteries/rechargeable
batteries together with household waste material.
Electric tools and batteries that have reached the end of
their life must be collected separately and returned to an
environmentally compatible recycling facility.
Check with your local authority or retailer for recycling
advice and collection point.
This tool is only suitable for indoor use. Never expose tool
to rain.
Time-lag fuse 5 A
T5.0A
Double isolated
European Conformity Mark
National mark of conformity Ukraine
EurAsian Conformity Mark.
ENGLISH
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

M12nrg-202

Table des Matières