7.3.5.1 ALARM
Use the Alarm menu to configure alarm and email settings.
I/O Alarm: each channel has one I/O alarm. When an alarm is triggered the corresponding channel
will start alarm record.
NO (Normal Open, when alarm in, close)
OFF (Normal Closed, when alarm in, open)
HDD LOSS: The alarm will sound if the internal HDD is damaged. The live screen will show [H].
HDD SPACE: when the space less then 500MB, the live screen will show 'not enough space'. Clear
data or replace HDD.
VIDEO LOSS: when a camera is disconnected, the live screen will show 'video loss'.
ALARM MANAGE:
alarm output: set the time of alarm output: 0, 10, 20, 40 or 60 seconds.
Buzz: set the time of buzz: 0, 10, 20, 40 or 60 seconds.
post record: set the record time after alarm: 30 Sec, 1, 2 or 5 Min.
EMAIL SETUP:
The system can send an email notification with a JPEG snapshot for triggered events on the system
every 3 minutes.
To setup email notification:
1) Under EMAIL, select ON.
2) Under SSL, select OFF.
NOTE: SSL deals with encryption. Only advanced users should enable this option.
3) Under SMTP PORT, enter the SMTP port of your email server.
4) Under SMTP, enter the SMTP address of your email server. For example, smtp.gmail.com
5) Under SEND EMAIL, enter the sender email address.
6) Under SEND PW, enter the password of your email server.
7) Under RECV EMAIL, enter the email address that will receive the email notification.
8) Click APPLY. Click SURE in the confirmation window.
9) Click EXIT in all menus until all windows are closed.