tau K206MA Notice D'installation page 20

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
9-10-11
Selection of barrier model and bar lenght
Dip 9
Dip 10
Off
Off
On
Off
Off
On
On
On
Off
Off
On
Off
Off
On
On
On
IMPORTANT: In case the boom length change, a new setting of the dips # 9, 10 and 11
will be required. Before the new setup, however, it is necessary to proceed to a HARD
RESET (see page 24) of the controller.
12
SENSITIVE EDGE
MEMORIZATION PROCEDURE
WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations.
Note: the mechanical stops of the bar must be regulated both in opening and in closing (see
barrier instructions).
When you have completed the installation procedures:
Check the position of dip-switches 9, 10 and 11. Dip-switches must be set according to
the barrier model and the bar length (see table of dip-switches 9-10-11, "Logic adjust-
ments" section).
It is recommended to start the learning process with the bar down.
Press without releasing the PROG button till the DL8 LED starts flashing (yellow):
-
the automation starts to open slowly looking for the opening limit stop;
If the automation closes instead of opening, stop the run of the gate (by cutting the pho-
tocells or closing the STOP contact), invert the polarity of the motor, take the gate in the
closed position (on the mechanical stop) and restart the procedure from the beginning.
Note: if the automation does not work, check the input connections. The DL6, DL5 and DL3
green LEDS must be on.
-
once the limit stop is reached, the automation starts closing looking for the closing limit stop (in
this phase the control unit gathers all the parameters regarding the run);
-
the automation carries out one complete opening to optimize the opening power;
-
after a short pause, the automation carries out one complete closure to optimize the closing power.
WARNING:
-
The procedure can be stopped by pressing the STOP button.
-
During the various stages of the operation, if the sensor is activated saving is stopped. To
restart the procedure from the beginning (with the DL8 yellow LED flashing), use the AP/
CH control, the remote control (if programmed) or press the PROG button briefly.
Please remember that an obstacle during saving is interpreted as a mechanical limit stop
(the system does not start any safety operation, it just stops the motors).
Make sure you don't stand near the bar during saving.
K206MA CHARACTERISTICS
TIMER-OPERATED OPENING AND CLOSING CYCLES
The opening/closing of the automation can be controlled by means of a timer that has a free N.O.
output contact (relay). The timer must be connected to terminals 4 - 6 (OPEN/CLOSE button) and can
20
Dip 11 Model
Off
RBLO / RBLO-X bar ≥ 2 m ≤ 2,5 m
Off
RBLO / RBLO-X bar > 2,5 m ≤ 3,5 m
Off
RBLO / RBLO-X bar > 3,5 m ≤ 4 m
Off
RBLO-L / RBLO-LX bar > 3,5 m ≤ 6 m
On
LUXE bar ≥ 4 m ≤ 4,5 m (including accessories)
On
LUXE bar > 4,5 m ≤ 5,5 m (including accessories)
On
LUXE bar > 5,5 m ≤ 6,5 m (including accessories)
On
LUXE bar > 6,5 m (including accessories)
On
RESISTIVE SENSITIVE EDGE (terminal No. 10).
FIXED EDGE (NC contact – terminal No. 10).
Off
Note: if not used, keep the DIP in the OFF position.
K206MA

Publicité

Table des Matières
loading

Table des Matières