1) FOREWORD
Designed to drive counterweight overhead doors.
Its compact design and mounting versatility mean the drive can be applied in
any overhead model, fitted either centrally or at the side. It is recommended for
residential use.
The irreversible gearbox keeps the door locked closed without the use of sole-
noid locks.
If the event of a mains power outage, the release is operated from the inside by
means of a special knob. It features limit switches that stop the motor both on
opening and closing as well as a timed courtesy light.
Available versions:
PHEBE N/PHEBE N IP44
Version with built-in control panel (HYDRA N) suitable for controlling one or
two operators.
PHEBE N SQ/PHEBE N SQ IP-44
Version with no control panel, essential for automated systems with two PHEBE
N actuators where the first is a PHEBE N and the second a PHEBE N SQ. Can also
be used when you want to mount the control panel on a wall.
PHEBE N C
Version for bi-fold overhead doors with built-in control panel (HYDRA N) suitable
for controlling one or two operators.
PHEBE N C SQ
Version for bi-fold overhead doors with no control panel, essential for automated
systems with two PHEBE N C actuators where the first is a PHEBE N C and the
second a PHEBE N C SQ. Can also be used when you want to mount the control
panel on a wall.
PHEBE N KIT
Version available as a kit. Suitable for overhead doors with leaf measuring up to
7m
, has built-in control panel Mod. HYDRA N.
2
WARNING: Operators without a built-in control panel must be controlled with a
control panel featuring electronic torque control (HYDRA N series).

2) TECHNICAL SPECIFICATIONS

Power supply
single-phase 230V ±10%, 50Hz (*)
Motor
24V
PHEBE N/PHEBE N SQ IP44/PHEBE N
Power input
PHEBE N C/PHEBE N-C SQ IP44/PHEBE N C IP44: 45W
Insulation class
F
Lubrication
Lifetime greased
Output shaft
Hollow through shaft 20X20
Opening time
17 ÷ 20 s
Supplied torque
PHEBE N/PHEBE N SQ IP44/PHEBE N IP44: 300Nm
PHEBE N C/PHEBE N-C SQ IP44/PHEBE N C IP44: 330 Nm
Operating limits
1 Motor for 7m
Impact reaction
Torque limiter built into HYDRA N control panel
Limit switches
Electric, built-in and adjustable
Manual operation
Knob-operated release
Type of use
Semi-intensive
~
Courtesy light
24V
Operating temperatu-
-15 +60° C
re range
PHEBE N/PHEBE N C: IP20
Protection rating
PHEBE N SQ IP44/PHEBE N IP44: IPX4
Electrical parts: IP44
Operator weight
10kg (≈10N)
Dimensions
See Fig. O
(*) Special supply voltages to order.
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
3) MOUNTING THE ACTUATOR ON BASE FIG.B
NOTE: it is advisable to wait until installation is complete before fitting the
actuator's cover using the four screws.
10 -
PHEBE N
INSTALLATION MANUAL
MOTOR
1500 min
-1
IP44: 40W
/ 2 Motor for 10m
2
2
Max 25W
4) MOUNTING THE MOTOR AND DRIVE SHAFTS ON DOOR FIG. C
WARNING: they must be fastened securely to the frame of the overhead door
and must be perfectly aligned with the centre of the hole in the actuator's shaft
Ref.3.
5) CUTTING EXCESS TUBES FIG. D
6) DOOR BALANCING Fig. E
Rif.1) BCORRECTLY BALANCED: when at 45° (released) the door is UNMOVING.
Rif.2) If the counterweights are made of iron, weld them on. If the door tends to
lower, add weight to the counterweights.
7) MOUNTING TELESCOPIC ARMS FIG. F-G-H-I-J
WARNING: Before turning the actuator's shaft, make sure the cams controlling
the limit microswitches turn freely (loosened).
Fig. G-H) Fastening the upper fitting
Fig. I)
Measuring and cutting telescopic arms
Cut the telescopic arms, keeping to the distances "D" on:
- Ref.1) Straight arms
- Ref.2) Curved arms.
Fig. J)
Make sure that, with the door closed, the telescopic arm is still 70-80
mm inside.
WARNING: if this is not the case, identify a more suitable position for
fitting "A" or use longer arms.
8) COUPLING TELESCOPIC SHAFT AND DRIVE TUBES FIG. K
9) ELECTRICAL SYSTEM FIG. L - M
The length of cable between the wall and moving door must have a sufficiently
long loop (Fig.M Ref.1) to allow for the door to move without the cable being
pulled taut.
10) DJUSTING THE LIMIT SWITCHES FIG. N
11) INSTALLATION ON OVERHEAD DOORS WITH VERTICAL AND HORIZON-
TAL GUIDES FIG. P
12) INSTALLATION ON BI-FOLD OVERHEAD DOORS (USING PHEBE N C) FIG. Q
13) CONFIGURATION AND WIRING FIG. R
Ref. 1) 1 PHEBE N or PHEBE N KIT with built-in control panel
Ref. 2) 1 PHEBE N SQ with wall-mounted control panel
Ref. 3) 2 PHEBE N SQ with wall-mounted control panel mod. HYDRA N
Ref. 4) 1 PHEBE N with built-in control panel mod. HYDRA N and 1 PHEBE N SQ
with no control panel.
14) MANUAL RELEASE (See USER GUIDE -FIG.1)
ACCESSORY FOR EXTERNAL RELEASE FIG.4
If the release device is being mounted on the outside, you will need to wind the
release lever's return spring.
15) REPLACING THE LIGHT BULB (See USER GUIDE -FIG.2)
WARNING: only use 24V~max. 25W E14 bulbs.
WARNING: never remove the protective sheath "G" when replacing the bulb.