Care And Maintenance; Cleaning And Drying; Transport; Hilti Calibration Service - Hilti PP 10 Mode D'emploi

Masquer les pouces Voir aussi pour PP 10:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29

8 Care and maintenance

8.1 Cleaning and drying

1.
Blow dust off the lenses.
2.
Do not touch the glass with your fingers.
3.
Use only a clean, soft cloth for cleaning. If necessary,
moisten the cloth slightly with pure alcohol or a little
water.
en
NOTE Do not use any other liquids as these may
damage the plastic components.
4.
Observe the temperature limits when storing your
equipment. This is particularly important in winter
/ summer if the equipment is kept inside a motor
vehicle (-30°C to +60°C).
8.2 Storage
Remove the tool from its case if it has become wet. The
tool, its carrying case and accessories should be cleaned
and dried (at maximum 40°C / F). Repack the equipment
only once it is completely dry.
Check the accuracy of the equipment before it is used
after a long period of storage or transportation.
Remove the batteries from the tool before storing it for a
long period.

9 Troubleshooting

Fault
E02/03
E99
ERROR

10 Disposal

WARNING
Improper disposal of the equipment may have serious consequences:
The burning of plastic components generates toxic fumes which may present a health hazard.
Batteries may explode if damaged or exposed to very high temperatures, causing poisoning, burns, acid burns or
environmental pollution.
Careless disposal may permit unauthorized and improper use of the equipment. This may result in serious personal
injury, injury to third parties and pollution of the environment.
22

8.3 Transport

Use the Hilti toolbox or packaging of equivalent quality
for transporting or shipping your equipment.
CAUTION
Always remove the batteries before shipping the tool.

8.4 Hilti calibration service

We recommend that the tool is checked by the Hilti cal-
ibration service at regular intervals in order to verify its
reliability in accordance with standards and legal require-
ments.
Use can be made of the Hilti calibration service at any
time, but checking at least once a year is recommended.
The calibration service provides confirmation that the
tool is in conformance, on the day it is tested, with the
specifications given in the operating instructions.
The tool will be readjusted if deviations from the man-
ufacturer's specification are found. After checking and
adjustment, a calibration sticker applied to the tool and
a calibration certificate provide written verification that
the tool operates in accordance with the manufacturer's
specification.
Calibration certificates are always required by companies
certified according to ISO 900x.
Your local Hilti Center or representative will be pleased
to provide further information.
Possible cause
An internal measurement problem has
occurred.
An internal memory problem has oc-
curred.
The tool was moved while in standby
mode.
Remedy
Switch the tool off and then on again.
An error message may be displayed
if the tool is knocked or shaken. In
this case, eliminate the cause of the
disturbance.
Switch the tool off and then on again.
Switch the tool off and then on again
and check that it is set up correctly.
NOTE
Contact your nearest Hilti Service
Center if the fault persists.

Publicité