5.

CONNECTION BLOCK CHART

5.1. ONE-HOUSEHOLD SYSTEM

OP4
2
OP5
2
2
OP1
2
OP6
(1) For dip-switch confi gurations see par. 7.2 DIP-SWITCH CONFIGURATION
The OP2 supplementary ringer may be connected to any video door phone in the system.

5.1.1. MAXIMUM DISTANCES BETWEEN DEVICES

Basic system with 1 video door phone
2Voice
Segment
cable
A1 - most distant
150 m / 492 ft 130 m / 426 ft 80 m / 262 ft
video door phone
C1 – C2
0,5 m / 1.6 ft
C2 – most distant
150 m / 492 ft 75 m / 246 ft 40 m / 131 ft
video door phone
A1 – OP1
20 m / 65 ft
A1 – OP4
50 m / 164 ft
A1 – OP5
20 m / 65 ft
A1 – OP6
20 m / 65 ft
B – OP2
30 m / 98 ft
System up to 4 video door phones
2Voice
Segment
cable
A1 - most distant
video door phone 150 m / 492 ft 130 m / 426 ft 80 m / 262 ft
C1 – C2
0,5 m / 1.6 ft
C2 – most distant
video door phone 150 m / 492 ft 75 m / 246 ft 40 m / 131 ft
A1 – OP1
20 m / 65 ft
A1 – OP4
50 m / 164 ft
A1 – OP5
20 m / 65 ft
A1 – OP6
20 m / 65 ft
B – OP2
30 m / 98 ft
DS1722-139
2
A1
C1
110/230 V~
SYT1
(Ø 0,8 mm /
CAT5/CAT6
AWG20)
0,5 m / 1.6 ft 0,5 m / 1.6 ft
10 m / 32 ft *
10 m / 32 ft
50 m / 164 ft
30 m / 98 ft
10 m / 32 ft *
10 m / 32 ft
10 m / 32 ft *
10 m / 32 ft
30 m / 98 ft
10 m / 32 ft
(*) SYT1 wire contains two pairs of wires inside. Use both to reach a distance of 20 m / 65 ft.
SYT1
(Ø 0,8 mm /
CAT5/CAT6
AWG20)
0,5 m / 1.6 ft 0,5 m / 1.6 ft
10 m / 32 ft *
10 m / 32 ft
50 m / 164 ft
30 m / 98 ft
10 m / 32 ft *
10 m / 32 ft
10 m / 32 ft *
10 m / 32 ft
30 m / 98 ft
10 m / 32 ft
(*) SYT1 wire contains two pairs of wires inside. Use both to reach a distance of 20 m / 65 ft.
B
Master
2
C2
OP3
Slave
2
Type of wire
Ø 0.6 mm / AWG22
0,5 mm
Twisted telephone
/ AWG20
wire without sheath
single cable
100 m / 328 ft
60 m / 196 ft 100 m / 328 ft 100 m / 328 ft 100 m / 328 ft
0,5 m / 1.6 ft
0,5 m / 1.6 ft 0,5 m / 1.6 ft
40 m / 131 ft
60 m / 196 ft 100 m / 328 ft 100 m / 328 ft 100 m / 328 ft
10 m / 32 ft
10 m / 32 ft
50 m / 164 ft
50 m / 164 ft 50 m / 164 ft
10 m / 32 ft
10 m / 32 ft
10 m / 32 ft
10 m / 32 ft
30 m / 98 ft
30 m / 98 ft
Type of wire
Ø 0.6 mm / AWG22
0,5 mm
Twisted telephone
/ AWG20
wire without sheath
single cable
100 m / 328 ft
60 m / 196 ft 100 m / 328 ft 100 m / 328 ft 100 m / 328 ft
0,5 m / 1.6 ft
0,5 m / 1.6 ft
40 m / 131 ft
60 m / 196 ft 100 m / 328 ft 100 m / 328 ft 100 m / 328 ft
10 m / 32 ft
10 m / 32 ft
50 m / 164 ft
50 m / 164 ft
10 m / 32 ft
10 m / 32 ft
10 m / 32 ft
10 m / 32 ft
30 m / 98 ft
30 m / 98 ft
OP2
2
2
(1)
2
(1)
OP3
Slave
0,75 mm
1 mm
2
2
/ AWG18
/ AWG17
single cable
single cable
0,5 m / 1.6 ft
10 m / 32 ft
20 m / 65 ft
50 m / 164 ft
10 m / 32 ft
20 m / 65 ft
10 m / 32 ft
20 m / 65 ft
30 m / 98 ft
30 m / 98 ft
0,75 mm
1 mm
2
2
/ AWG18
/ AWG17
single cable
single cable
0,5 m / 1.6 ft
0,5 m / 1.6 ft
10 m / 32 ft
20 m / 65 ft
50 m / 164 ft
50 m / 164 ft
10 m / 32 ft
20 m / 65 ft
10 m / 32 ft
20 m / 65 ft
30 m / 98 ft
30 m / 98 ft
OP3
(1)
2
Slave
1,5 mm
2
2
/ AWG15
single cable
0,5 m / 1.6 ft
20 m / 65 ft
50 m / 164 ft
20 m / 65 ft
20 m / 65 ft
30 m / 98 ft
1,5 mm
2
2
/ AWG15
single cable
0,5 m / 1.6 ft
20 m / 65 ft
50 m / 164 ft
20 m / 65 ft
20 m / 65 ft
30 m / 98 ft