Connection Instructions; Technical Specifications - Urmet elekta 1060/13 Mode D'emploi

Masquer les pouces Voir aussi pour elekta 1060/13:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3 CONNECTION INSTRUCTIONS

Refer to the instructions contained in the system manual for wiring, maximum distances and confi guration
operations.
3.1 CONNECTOR AND WIRING WITH CAT5 WIRE
Use Urmet RJ45 connector kit for connections (product on sale until stocks last).
Connect the CAT5 wire to one of the RJ45 connectors with Urmet logo:
Insert the wire in the guide respecting the colour coding shown (Standard T568B).
Cut the wires which protrude from the guide by approximately 5mm, insert the guide in the plug and
crimp the plug with a specifi c tool.
Make sure that the grey sheath remains inside the plug.
This type of connection DOES NOT ensure double insulation.

4 TECHNICAL SPECIFICATIONS

Power voltage and consumption on terminals V+ e V-
Power voltage: ............................................................................................................................... 44 – 57 Vdc
Consumption video call @48V: .............................................................................................................160 mA
Consumption stand-by @48V: .............................................................................................................100 mA
Working temperature range: .................................................................................................. -10 °C ÷ +50 °C
Relay contact range C, NC, NO:
Maximum switching voltage: .................................................................................................................... 30 V
Maximum switching current: ...................................................................................................................3,5 A
Maximum switching load: ............................................................................................................. 40 VA 25 W
Garage gate relay contact range (SE2):
Maximum switching voltage: .................................................................................................................... 30 V
Maximum switching current: ...............................................................................................................200 mA
Max. distance from hall button: .............................................25 m with cable cross-section area 0.5 mm
Max. distance from open door sensor: .................................50 m with cable cross-section area 1.5 mm
Max. distance from supplementary power supply: .............100 m with cable cross-section area 1.5 mm
Max. distance from capacitance lock: ................................100 m with cable cross-section area 1.5 mm
8
Wire
No.
1
White-Orange
2
Orange
1
3
White-Green
4
Blue
8
~ 5 mm
1
8
Wire colour
1
8
Wire
Wire colour
No.
5
White-Blue
6
Green
7
White-Brown
8
Brown
Plug
DS1060-117A
2
2
2
2

Publicité

Table des Matières
loading

Table des Matières