To Convert Standard Surface Burners
1. Remove burner cap.
2. Remove burner base.
3. Apply masking tape to the end of a 7.0 mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise and lifting out. Set gas orifice
spud aside.
A. Orifice spud
4. Gas orifice spuds are stamped with a number on the side.
A. Stamped number
Refer to the following chart for correct LP gas orifice spud
placement.
LP Gas Orifice Spud Chart for Standard Surface Burners
Burner Location
Burner Rating
Right front
3,5000 Btu/h
Left front
6,000 Btu/h
Center
11,000 Btu/h
Right rear
6,000 Btu/h
Left rear
10,000 Btu/h
5. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with literature package.
6. Repeat steps 1-6 for the remaining burners.
7. Replace burner base, burner head and burner cap.
8. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with literature package.
9. Complete installation. See "Make Gas Connection" and
"Electronic Ignition System" sections.
Checking for proper cooktop burner flames is very important.
The small inner cone should have a very distinct blue flame
¼" to ½" long. The outer cone is not as distinct as the inner
cone. LP gas flames have a slightly yellow tip.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner. See "Make Gas Connection" and
"Electronic Ignition System" section.
18
A
A
Size
0.53 mm
0.73 mm
1.00 mm
0.73 mm
0.93 mm

Natural Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect wall anti-tip brackets to wall behind range.
Connect range anti-tip brackets to underside of range.
Re-engage the anti-tip brackets, if the range is moved.
See the installation instructions for details.
Failure to follow these instructions can result in death
or serious burns to children and adults.
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the "closed" position.
2. Unplug range or disconnect power.
A
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
3. Remove access cover from the gas pressure regulator.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
B
C
A