Technical Data; Conditions Of Use; Conformity To Standards And Directives - Burkert 8081 Manuel Utilisateur

Masquer les pouces Voir aussi pour 8081:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Type 8081
Technicaldata
G 1 1/4'' ex-
ternal thread
1 to
6
25
200 l/min
NPT 1 1/4''
external
thread
Pulse, NPN
560132
Pulse, PNP +
4-20 mA, sourcing
560114
mode
Pulse, NPN
560616
Pulse, PNP +
4-20 mA, sourcing
560621
mode
6.

TechnicAl dATA

6.1.

conditions of use

Ambient temperature:
+5 to +55 °C
Storage temperature:
+5 to +55 °C
Air humidity:
< 80%, not condensated
Protection rating:
IP65 with cable plug plugged-in and
tightened
6.2.
conformity to standards and
directives
EMC: EN61000-6-3, 61000-6-2
Vibration: EN 60068-2-6
Shock: EN 60068-2-27
Pressure: complying with article 3 of §3 from 97/23/CE directive
For the 97/23/CE pressure directive, the device can only be used in
the following cases (depending on max. pressure, pipe diameter and
fluid)
type of fluid
Fluid group 1, §1.3.a
Fluid group 2, §1.3.a
Fluid group 1, §1.3.b
Fluid group 2, §1.3.b
english
conditions
Forbidden
Allowed (PN*DN
1000)
Forbidden
Allowed